142
13. File Operations
The HVS-3800HS/S Hanabi switchers are capable of storing operational data to the CF memory
card and also of recalling and downloading previous card saved data for application to production
operations. Operational data which can be card saved / downloaded includes still images, WIPE
data, and system setup data.
13-1. CF Card
For available CF memory cards, see "Available File List" in the Appendix. Inserting and
removing of the CF card should be performed slowly and firmly.
Card Access Lamp
The indicator at the CF card drive turns red when saving or reading data to/from the CF card.
Check access to the CF card while performing the operations. While viewing the FILE menu, the
FILE button lights orange.
IMPORTANT
Do not remove the CF card while the FILE button is lit red. This could corrupt the
stored data or damage the card.
Card Space Indicator
To check the available space, insert the CF card into the card slot, and then press the FILE
button to open the FILE menu. The available space in the inserted CF card is displayed at the
top right of the FILE menu.
13-2. Saving Data to CF Cards
Operational data files can be saved to memory card using the following procedure.
First insert a CF card into the card drive.
Press the FILE button to display the FILE top menu. In the FILE menu, turn F1 to select 2
OU/MU=>FILE, and then press F1 or the DOWN button to open the submenu.
Use the TYPE item in the menu to select the file extension of data you want to save to the
card. See "Available File List" in the Appendix 2 for which file formats of the operational data
can be saved to card by HVS-3800 series switchers.
If multiple files are displayed in the menu, turn F2 and use SELECT to select which file you
want to save.
Once you have selected the file you want to save to, press F3 to send the file to the CF card.
A message "RENAME or SAVE?" will pop up. Turn F4 to select SAVE to save the data. If you
want to rename the file, select RENAME and then refer to the section 13-5 "Renaming Saved
Files" to give a new name to the file. If the same file exists in the CF card already, a message
"OVERWRITE?" will pop up that warns you that if you overwrite the existing file. Turn F4 to
select CANCEL, OVERWR (overwrite) or RENAME. If you want to overwrite the file, select
OVERWR. If you want to cancel the operation, select CANCEL.
A "beep" sound will be heard when the data is sent.