90
Offset for Fader Lever
The offset for the fader lever can be adjusted in the FADER item on the OU SETUP - FADER
menu. It is also possible to enable the fader's TIE function (refer to section 6-5.
"Simultaneous (TIE) Transitions").
Parameter
Description
Default
Setting Range
FADER
OFFSET
LOW
Offset of bottom part of fader lever
1.00
0.00 to 1.00
HIGH
Offset of top part of fader lever
1.00
0.00 to 2.00
TIE
Fader TIE function setting
OFF
ON, OFF
6-9-4. Fader Insensitive Region
The fader insensitive (flat) region can be set during transition. This setting can be made for
each M/E.
Press the OU SETUP button to display the OU SETUP top menu.
Turn F1 to select 4.FADER, press F1 or the DOWN button to open the FADER menu,
and then press the DOWN button to go to the FADER(2/2) menu.
Turn F1 under the SELECT item to select 0. The cursor goes to the M/E1 fader setting.
If 1 is selected, the cursor goes to the M/E2 fader setting.
Move the fader lever to the starting point of an insensitive region. Change the SET item to
IN, then press F3 to set the current fader position to the beginning of the region. You can
also set it manually by turning F5 to select a number and pressing F3.
Move the fader lever to the starting point of an insensitive region. Change the SET item to
OUT, then press F3 to set the current fader position to the end of the region. You can also
set it manually by turning F6 to select a number and pressing F3.
Change the ENABLE item to ON, then press F4 to apply the setting.
Parameter
Default
Setting Range
Description
SELECT
0
0, 1
Selects M/E
SET
IN
IN, OUT
Selects IN (beginning) or OUT (end).
ENABLE (*1)
OFF
OFF, ON
Enables/Disables insensitive region.
POINT
1
0.0
0.0 to 100.0
Sets starting position.
2
100.0
0.0 to 100.0
Sets end position.
NOTE
Insensitive region is effective in all transitions (MIX, NAM, FAM, WIPE and DVE). It is
not effective, however, in auto transition (by using the AUTO button).
Insensitive region is not effective when the TIE is ON.
OU SETUP
FADER(2/2)
ME1 FADER INSENSITIVE
ME2 FADER INSENSITIVE
SELECT
0
SET
IN
ENABLE
ON
40.0
0.0
IN
40.0
OUT
60.0
ON
OFF
60.0
100.0