11-2-12. Exiting Sequence Editing
To exit sequence editing, set NUMBER to OFF in the SEQUENCE (1/4) menu.
11-2-13. Deleting Sequences
This procedure deletes all setting information in a sequence.
Select the sequence to be deleted under the NUMBER item in the SEQUENCE(1/4)
menu.
Set DELETE to ON in the SEQUENCE(1/4) menu.
Press F3 to perform the delete operation. If pressing F3 with OFF will cancel the
operation.
11-2-14. Storing/Loading Each Sequence to CF Card
Each sequence data can be stored to and loaded from a CF card. Refer to section 13-2.
"Saving Data to CF Cards" and section 13-3. "Downloading from CF Cards" for how to store
and load a sequence.
11-3. Playing Back Sequences
Sequences are played back using the
SEQUENCE menu
and
keypad
. To play back a
sequence, change the OU to
SEQUENCE mode
, and then change the keypad to SEQUENCE
editing for operation.
IMPORTANT
When the keypad is mentioned in this section, it normally refers to the
SEQUENCE
Mode
keypad.
Operation item
Operation section
Operation
Refer
to
1
Open the SEQUENCE
menu
Keypad
Press the SEQ button.
11-2-1
2
Select the sequence
SEQUENCE menu
Select the number under the NUMBER
item (change OU to SEQUENCE MODE). 11-2-2
3
Playback
setting
Crosspoint
ON/OFF
SEQUENCE menu
Set if the crosspoint selection saved in the
sequence is used during playback for each
transition.
11-3-2
Bus information
ON/OFF
SEQUENCE menu
Set if the bus data saved in the sequence
(crosspoint selection, transition, transition
type selection) is used during playback for
each transition.
11-3-3
Transition
ON/OFF
SEQUENCE menu
Set if each transition is played back or not. 11-3-4
Fader link
setting
SEQUENCE menu
Set FADER LINK to ON
Playback
direction
SEQUENCE menu
Use the DIR item to set.
11-3-5
Break
SEQUENCE menu
Use the FL-BRK item to set.
11-3-6
Loop playback
SEQUENCE menu
Set LOOP to ON
11-3-1
Step playback
SEQUENCE menu
Set PLAY MODE to STEP.
* Playback
Keypad
Press PLAY for automatic playback.
BLACK TRANS button Assign playback function and use as PLAY
button.
* If the SEQ button above the keypad is not lit orange, press the button to light up orange. The keypad
section enters SEQ mode.
Summary of Contents for HVS-12ROUA
Page 25: ...11 Circuit Max voltage 40V External Device HVS 3800HS S Max load current 100mA...
Page 240: ......
Page 248: ......