Versiv Series Cabling Certification Product Family
Technical Reference Handbook
150
DIAGNOSTIC and FAULT INFO Tabs
If the Autotest failed or had a marginal result, the
FAULT INFO
tab shows. If the test passed and you selected
All Autotests
for
the
HDTDR/HDTDX
setting on the
TEST SETUP
screen, the
DIAGNOSTIC
tab shows. These tabs let you see the HDTDR and
HDTDX analyzer plots. The plots help you find the causes of NEXT
and return loss failures. See Chapter 6.
About dB Rules
For some test limits, the tester ignores the PASS/FAIL result from
some tests when a measurement is less than a specified value. For
example, the return loss measurement is not evaluated against
the limit at frequencies where insertion loss is less than 3 dB. This
is the 3 dB rule.
When a measurement is not evaluated against a limit, the tester
shows an for the result. On the plot for that measurement, the
limit line is black where the result is not evaluated against the
limit, as shown in Figure 69. When you upload the results to
LinkWare PC,
N/A
shows for the result.
The next sections summarize the dB rules. Tables 4 and 5 show the
dB rules that apply to each test and the test limits that use the
rules. For more information, see the Knowledge Base on the Fluke
Networks website.
Summary of Contents for CableAnalyzer DSX-5000
Page 24: ...xxii Versiv Series Cabling Certification Product Family Technical Reference Handbook...
Page 34: ...xxxii Versiv Series Cabling Certification Product Family Technical Reference Handbook...
Page 220: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 184...
Page 268: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 232...
Page 330: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 294...
Page 338: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 302...
Page 592: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 556...
Page 604: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 568...
Page 620: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 584...
Page 672: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 636...
Page 676: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 640...
Page 688: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 652...