Chapter 3: Certify Twisted Pair Cabling
Frequency-Domain Results
137
If the DC resistance of the wires is not the same, the DC voltage
on each wire is not the same. This causes a voltage across the
wires, which causes an offset, or bias, current in the transformer
at the far end. The offset raises or lowers the mid-point of the
transformer’s operation. If the offset is large enough, the flux
level in the transformer’s core saturates during the peaks of the
data signals. During saturation, the flux level in the core cannot
increase further in response to the change in current caused by
the data signal. Since voltage on a transformer’s output is present
only when the flux field is changing, the output voltage droops.
This causes distortion of the data signal, as shown at the bottom
of Figure 61.
Resistance unbalance within pairs can be caused by poor-quality
terminations, damaged connectors, corroded contacts, and
damaged or poorly-designed cable.
Figure 62 shows test results for resistance unbalance within pairs.
Summary of Contents for CableAnalyzer DSX-5000
Page 24: ...xxii Versiv Series Cabling Certification Product Family Technical Reference Handbook...
Page 34: ...xxxii Versiv Series Cabling Certification Product Family Technical Reference Handbook...
Page 220: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 184...
Page 268: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 232...
Page 330: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 294...
Page 338: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 302...
Page 592: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 556...
Page 604: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 568...
Page 620: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 584...
Page 672: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 636...
Page 676: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 640...
Page 688: ...Versiv Series Cabling Certification Product Family Technical Reference Handbook 652...