GD350A series high-performance multifunction VFD
-224-
Function
code
Name
Description
Default Modify
Range: -3276.8–3276.7Hz
P18.18
Pulse command
feedforward
Pulse command (A2, B2 terminal) is
converted to the set frequency, and it is valid
under pulse position mode and pulse speed
mode.
Range: -3276.8–3276.7Hz
0.00Hz
●
P18.19
Position regulator
output
-327.68–327.67Hz
0.00Hz
●
P18.20
Count value of
resolver
Count value of resolver.
Range: 0–65535
0
●
P18.21
Resolver angle
The pole position angle read according to the
resolver-type encoder.
Range: 0.00–359.99
0.00
●
P18.22
Pole angle of
closed-loop SM
Current pole position.
Range: 0.00–359.99
0.00
●
P18.23
Status control word
3
0–65535
0
●
P18.24
High-order bit of
count value of pulse
reference
Pulse command (A2,B2) count value. The
count value is accumulated only if the VFD is
powered on.
0–65535
0
●
P18.25
Low-order bit of
count value of pulse
reference
Pulse command (A2,B2) count value. The
count value is accumulated only if the VFD is
powered on.
0–65535
0
●
P18.26
PG card measured
speed value
-3276.8–3276.7Hz
0.0Hz
●
P18.27
Encoder UVW
sector
0–7
0
●
P18.28
Encoder PPR
(pulse-per-
revolution) display
0–65535
0
●
P18.29
Angle
compensation value
of SM
-180.0–180.0
0.0
●
P18.30
Reserved
0–65535
0
●
P18.31 Pulse reference Z 0–65535
0
●