![Esco invt GD350A Series Product Manual Download Page 51](http://html1.mh-extra.com/html/esco/invt-gd350a-series/invt-gd350a-series_product-manual_2426081051.webp)
GD350A series high-performance multifunction VFD
-46-
5.4.4 Add parameter to common parameter setup list
In fourth-level menu of "parameter setup" menu, the parameter in the list can be added to the "common
parameter setup" list as shown below.
01
:
GD350A
16:02:35
Forward
Local Ready
Add
Return
Select
P01.00
:
Running mode of start
P01.01
:
Starting frequency of direct start
P01.02
:
Hold-up time of starting frequency
P01.03
:
Brake current before start
P01.04
:
Brake time before start
P01.05
:
Acceleration/deceleration mode selection
01
:
GD350A
16:02:35
Homepage
Return
Confirm
Sure to add to common parameter
setup?
Forward
Local
Ready
Figure 5.14 Add parameter diagram 2
Add
key to enter addition interface, and press
key,
key or
key to confirm the
addition operation. If this parameter is not included in the original "common parameter setup" list, the
newly-added parameter will be at the end of the list; if this parameter is already in the "common
parameter setup" list, the addition operation will be invalid. If
key or
key is pressed without
selecting addition operation, it will return to parameter setup list menu.
All the function code groups under parameter setup sub-menu can be added to "common parameter
setup" list. Up to 64 function codes can be added to the "common parameter setup" list.
5.4.5 Parameter selection edit interface
In the fourth-level menu of "parameter setup" menu, press
key,
key or
key to enter
parameter selection edit interface. After entering edit interface, current value will be highlighted. Press
key and
key to edit current parameter value, and the corresponding parameter item of
current value will be highlighted automatically. After parameter selection is done, press
key or
key to save the selected parameter and return to the previous menu. In parameter selection edit
interface, press
key to maintain the parameter value and return to the previous menu.
Current value
:
0
Authority
:√
Homepage
Return
Confirm
0
:
SVC 0
1
:
SVC 1
2
:
V/F mode
3
:
VC mode
Current value
:
1
Authority
:√
Homepage
Return
Confirm
1
:
SVC 1
2
:
V/F mode
3
:
VC mode
Default value
:
2
Default value
:
2
01
:
GD350A
16:02:35 Forward
Local Ready
Add
Return
Select
P00.00
:
Speed control mode
P00.01
:
Running command channel
P00.02
:
Communication command channel
P00.03
:
Max. output frequency
P00.04
:
Upper limit of running frequency
P00.05
:
Lower limit of running frequency
Figure 5.15 Parameter selection edit interface
In parameter selection edit interface, the "authority" on the top right indicates whether this parameter
is editable or not.
"
√
" indicates the set value of this parameter can be modified under current state.
"×" indicates the set value of this parameter cannot be modified under current state.
"Current value" indicates the value of current option.