![Esco invt GD350A Series Product Manual Download Page 185](http://html1.mh-extra.com/html/esco/invt-gd350a-series/invt-gd350a-series_product-manual_2426081185.webp)
GD350A series high-performance multifunction VFD
-180-
Function
code
Name
Description
Default Modify
P06.16
HDO high-speed
pulse output
1: Set frequency (0–Max. output frequency)
2: Ramp reference frequency (0–Max. output
frequency)
3: Rotational speed (0–Speed corresponding
to max. output frequency)
4: Output current (0–Twice the VFD rated
current)
5: Output current (0–Twice the motor rated
current)
6: Output voltage (0–1.5 times the VFD rated
voltage)
7: Output power (0–Twice the motor rated
power)
8: Set torque (0–Twice the motor rated
current)
9: Output torque (Absolute value, 0–+/- Twice
the motor rated torque)
10: AI1 input (0–10V/0–20mA)
11: AI2 input (0–10V)
12: AI3 input (0–10V/0–20mA)
13: HDIA input(0.00–50.00kHz)
14: Value 1 set through Modbus/Modbus TCP
(0–1000)
15: Value 2 set through Modbus/Modbus TCP
(0–1000)
16: Value 1 set through
PROFIBUS/CANopen/DeviceNet (0–1000)
17: Value 2
set through
PROFIBUS/CANopen/DeviceNet (0–1000)
18: Value 1 set through Ethernet 1 (0–1000)
19: Value 2 set through Ethernet 2 (0–1000)
20: HDIB input (0.00–50.00kHz)
21: Value 1 set through
EtherCat/Profinet/EtherNetIP (0–1000)
22: Torque current (bipolar, 0–Triple the
motor rated current)
23: Exciting current (bipolar, 0–Triple the
motor rated current)
0
○