GD350A series high-performance multifunction VFD
-217-
Function
code
Name
Description
Default Modify
P15.29
Master/slave CAN
communication
baud rate selection
0: 50Kbps
1: 100 Kbps
2: 125Kbps
3: 250Kbps
4: 500Kbps
5: 1M bps
2
◎
P15.30
Master/slave CAN
communication
timeout time
0.0 (invalid)–300.0s
0.0s
○
P15.31–
P15.69
See the communication expansion card operation manual.
P16 group––Functions of communication expansion card
P16.00–
P16.23
See the communication expansion card operation manual.
P16.24
Time for identifying
expansion card at
slot 1
0.0–600.0s
If it is set to 0.0, identifying faults are not
detected.
0.0s
○
P16.25
Time for identifying
expansion card at
slot 2
0.0–600.0s
If it is set to 0.0, identifying faults are not
detected.
0.0s
○
P16.26
Time for identifying
expansion card at
slot 3
0.0–600.0s
If it is set to 0.0, identifying faults are not
detected.
0.0s
○
P16.27
Communication
timeout time for
expansion card at
slot 1
0.0–600.0s
If it is set to 0.0, identifying faults are not
detected.
0.0s
○
P16.28
Communication
timeout time for
expansion card at
slot 2
0.0–600.0s
If it is set to 0.0, identifying faults are not
detected.
0.0s
○
P16.29
Communication
timeout time for
expansion card at
slot 3
0.0–600.0s
If it is set to 0.0, identifying faults are not
detected.
0.0s
○
P16.30–
P16.69
See the communication expansion card operation manual.