![Esco invt GD350A Series Product Manual Download Page 162](http://html1.mh-extra.com/html/esco/invt-gd350a-series/invt-gd350a-series_product-manual_2426081162.webp)
GD350A series high-performance multifunction VFD
-157-
Function
code
Name
Description
Default Modify
9: Pulse frequency HDIB (same as the above)
10:
EtherCat/Profinet/EthernetIP
communication
11: Programmable expansion card
12: Reserved
P03.16
Forward rotation
upper-limit
frequency set
through keypad in
torque control
The function codes are used to set the
frequency upper limits. 100% corresponds to
the max. frequency. P03.16 sets the value
when P03.14=1; P03.17 sets the value when
P03.15=1.
Setting range: 0.00Hz–P00.03 (Max. output
frequency)
50.00Hz
○
P03.17
Reverse rotation
upper-limit
frequency set
through keypad in
torque control
50.00Hz
○
P03.18
Setting source of
electromotive
torque upper limit
0: Keypad (P03.20)
1: AI1 (100% corresponding to three times the
motor rated current)
2: AI2 (same as the above)
3: AI3 (same as the above)
4: Pulse frequency HDIA (same as the above)
5: Modbus/Modbus TCP communication
(same as the above)
6: Profibus/CANopen/DeviceNet
communication (same as the above)
7: Ethernet communication (same as the
above)
8: Pulse frequency HDIB (same as the above)
9:
EtherCat/Profinet/EthernetIP
communication
10: Programmable expansion card
11: Reserved
0
○
P03.19
Setting source of
braking torque
upper limit
0: Keypad (P03.21)
1: (100% corresponding to three times the
motor rated current)
2: AI2 (same as the above)
3: AI3 (same as the above)
4: Pulse frequency HDIA (same as the above)
0
○