![Esco invt GD350A Series Product Manual Download Page 242](http://html1.mh-extra.com/html/esco/invt-gd350a-series/invt-gd350a-series_product-manual_2426081242.webp)
GD350A series high-performance multifunction VFD
-237-
Function
code
Name
Description
Default Modify
0: Calibrate at the first time
1: Calibrate in real time
Bit8: Action selection after zeroing signal
cancellation (electric level type)
0: Switch to speed mode
1: Position lock mode
Bit9: Positioning completion signal selection
0: Electric level signal
1: Pulse signal
Bit10: Z pulse signal source
0: Motor
1: Spindle
Bit11–15: Reserved
P22.01
Speed of spindle
orientation
During spindle orientation, the speed of the
position point of orientation will be searched,
and then it will switch over to position control
orientation.
Setting range: 0.00–100.00Hz
10.00Hz
○
P22.02
DEC time of spindle
orientation
DEC time of spindle orientation.
Spindle orientation DEC time means the time
needed for the VFD to decelerate from Max.
output frequency (P00.03) to 0Hz.
Setting range: 0.0–100.0s
3.0s
○
P22.03
Spindle zeroing
position 0
You can select the zeroing positions of four
spindles by terminals (function code 46, 47).
Setting range: 0–65535
0
○
P22.04
Spindle zeroing
position 1
Setting range: 0–65535
0
○
P22.05
Spindle zeroing
position 2
Setting range: 0–65535
0
○
P22.06
Spindle zeroing
position 3
Setting range: 0–65535
0
○
P22.07
Spindle scale-
division angle 1
You can select seven spindle scale-division
values by terminals (function code 48, 49 and
50).
Setting range: 0.00–359.99
15.00
○
P22.08
Spindle scale-
Setting range: 0.00–359.99
30.00
○