GD350A series high-performance multifunction VFD
-44-
Level 1
Level 2
Level 3
Level 4
Backlight brightness regulation
Backlight time adjustment
Power-on guiding enable
Power-on guiding settings
Keyboard burning selection
Fault time enable
Control board burning selection
5.4.2 List edit
The monitoring items displayed in the parameter list of stop state can be added by users as needed
(through the menu of the function code in state check group), and the list can also be edited by users
e.g. "shift up", "shift down" and "delete from the list". The edit function is shown in the interface below.
01: GD350A
16:02:35
Homepage
Return
Select
Shift up
Shift down
Delete from the list
16:02:35
Forward Local
Ready
Homepage
Return
Select
Parameter displayed in stop state
Parameter displayed in running state
01: GD350A
16:02:35
Edit
Return
Confirm
P17.00
:
Set frequency
P17.11
:
DC bus voltage
P17.12
:
Digital input terminal state
P17.13
:
Digital output terminal state
P17.23
:
PID reference value
P17.24
:
PID feedback value
01: GD350A
Forward Local
Ready
Forward Local
Ready
Figure 5.10 List edit diagram 1
Press
key to enter edit interface, select the operation needed, and press
key,
key
or
key to confirm the edit operation and return to the previous menu (parameter list), the returned
list is the list edited. If
key or
key is pressed in edit interface wihouth selecting
edit operation, it will return to the previous menu (parameter list remain unchanged).
Note:
For the parameter objects in the list header, shift-up operation will be invalid, and the same
principle can be applied to the parameter objects in the list footer; after deleting a certain parameter,
the parameter objects under it will be shifted up automatically.
The monitoring items displayed in the parameter list of running state can be added by users as needed
(through the menu of the function code in state check group), and the list can also be edited by users
e.g. "shift up", "shift down" and "delete from the list". The edit function is shown in the interface below.
01: GD350A
16:02:35
Shift up
Shift down
Delete from the list
16:02:35
Edit
Return
Confirm
P17.01
:
Output frequency
P17.00
:
Set frequency
P17.11
:
DC bus voltage
P17.03
:
Output voltage
P17.04
:
Output current
P17.05
:
Motor speed
01: GD350A
01: GD350A
16:02:35
Parameter displayed in stop state
Parameter displayed in running state
Forward Local
Ready
Forward Local
Ready
Forward Local
Ready
Homepage
Return
Select
Homepage
Return
Select
Figure 5.11 List edit diagram 2
The parameter list of common parameter setup can be added, deleted or adjusted by users as needed,