GD350A series high-performance multifunction VFD
-235-
Function
code
Name
Description
Default Modify
P21.24
Home position
offset
0–65535
0
○
P21.25
Hold time of
positioning
completion signal
The hold time of positioning completion signal,
the function code is also valid for positioning
completion signal of spindle orientation.
Setting range: 0.000–60.000s
0.200s
○
P21.26
value
P21.26: -9999–32767
P21.27: 0–3000.0/ms
The function is valid only when P00.06=12 or
P21.00=1:
1: Input terminal function 68
When the terminal rise edge is detected, the
pulse setting is increased by P21.26, and the
pulse given channel is compensated at the
rate specified by P21.27.
2: Input terminal function 67
When the terminal is valid, the pulse value is
superposed to the pulse given channel at the
rate specified by P21.27.
P05.09 may have slight impact on the
actual superposition value.
Example:
P21.27 = 1.0/ms
P05.05 = 67
When the S5 terminal input signal is 0.5s, the
actual number of pulses superposed is 500.
3: Input terminal function 69
The timing sequence of this value is the same
as that of the previous value, with the only
difference that the number is negative.
Note:
The pulses are superposed to the pulse
given channels (A2 and B2), and the functions
such as the filter and electric cam for pulses
are valid for superposed pulses.
4: Input terminal function 28
The output terminal is valid during pulse
superposition, but it is invalid after pulse
superposition.
0
○
P21.27
Pulse superposition
speed
8.0/ms
○
P21.28
pulse disabling
5.0s
○