GD350A series high-performance multifunction VFD
-229-
Function
code
Name
Description
Default Modify
division output filter
0: No filter
1: Filter
Bit3: Reserved
Bit4: Enable/disable pulse reference filter
0: No filter
1: Filter
Bit5: Pulse reference filter mode (valid when
Bit4 is set to 1)
0: Self-adaptive filter
1: Use P20.19 filter parameter
Bit6: Frequency-divided output source setting
0: Encoder signals
1: Pulse reference signals
Bits7–15: Reserved
P20.18
Encoder pulse filter
width
0–63
The filtering time is P20.18*0.25
μ
s. The value
0 or 1 indicates 0.25
μ
s.
2
○
P20.19
Pulse reference
filter width
0–63
The filtering time is P20.19*0.25
μ
s. The value
0 or 1 indicates 0.25
μ
s.
2
○
P20.20
Pulse number of
pulse reference
0–65535
1024
◎
P20.21
Enable angle
compensation of
SM
0–1
0
○
P20.22
Switchover
frequency threshold
of speed
measurement mode
0–630.00Hz
Note:
Valid only when P20.12=0
1.00Hz
○
P20.23
SM angle
compensation
coefficient
-200.0–200.0%
100.0%
○
P20.24
Reserved
0–65535
0
○
P21 group––Position control
P21.00 Positioning mode
Ones place: Control mode selection (only for
closed-loop vector control)
0x0000
○