Q:  

Whenever I press “read” under projector controls in the control software, I get partial data 

filled in. How do I confirm good communication and get all default fields filled in? 

A:  Please ensure you have good RS-232 cable. Sometimes communication can hang, please 
disconnect the 3.5mm to 9-pin adapter cable from the AT-HDVS-RX and reconnect to solve this 
issue. 

Q:  Does this unit require a Null Modem adapter/cable to connect to a display? 

A: The need for a Null modem adapter is based on the requirements of your RS-232 enabled 
display. Please refer to the manufacturer manual for proper pin configuration. 

 

 

 

 

Q:  I am having problem setting up the system, what could I be doing wrong? 

 

A:  Please refer to this video for instructions. 

 
Q:  I get HDMI audio just fine but not through VGA. 

A:  Please check the audio settings in the Receiver’s Menu as you will need to select L/R audio for 
the 3.5mm to be used. 

 
Q:  Even if the source is unplugged via AT-HDVS-TX/RX, does it still send a signal to the 
projector or TV? 

A:  Yes. Because the AT-HDVS-RX is also a scaler with OSD so there is always a signal/5V presence 
on the video out. As a result, it is not recommended to use AT-HDVS-RX with auto-sensing 
switches. 
 

Q:  RS-232 power commands are not storing in the HDVS-RX. After you Send the commands, 
Read is not populating the commands (clears anything in the Display On / Display Off 
window). 

 

A:  First Unplug everything (power, category cable and HDMI) from the HDVS-RX for 10 seconds. 
Reconnect everything and wait until the video returns. Try sending the RS-232 commands again. 
If the first suggestion does not fix the issue try typing in the RS-232 commands, Save the 
configuration, Load that configuration and then Send/Read. Verify that the commands have 
stored. 

Q:  RS-232 commands are not coming through as they were entered, text and or hex are 
random characters. 
 

A:  Make sure the RS-232 stereo plug is fully seated. Being not fully seated can cause the RS-232 
characters to become random data. Make sure that only the HDVS-RX is powered. If the 
customer is using the HDVS-TX, they should not be using it’s power supply when using the HDVS-
RX. 

 