Appendix D
Transmitter components and installation
wiring
Topics covered in this appendix:
•
•
•
Input/output (I/O) wiring terminals
D.1
Installation types
The transmitter was ordered and shipped to be installed in one of two possible
configurations.
4-wire remote installation
Figure D-1:
The transmitter is installed remotely from the sensor. The 4‐wire connection between the sensor and
transmitter must be field wired. Power supply and I/O must be field wired to the transmitter.
SENSOR
ZERO
ST
ATUS
OUTPUTS
SUPP
LY
24 VDC
+
A
-
21
22
23
24
31
32
33
34
11
12
13
14
+ B
-
+ C
-
A4B5 B
B
A
-
+
4
3
2
1
A
A
A
B
C
D
A.
Transmitter
B.
Field‐wired 4‐wire connection
C.
Core processor
D.
Sensor