Field Communicator connection to transmitter terminals
Figure B-1:
A. Field Communicator
B.
250–600
Ω
resistance
C. Transmitter terminals
2.
To connect to a point in the local HART loop, attach the leads from the
Field Communicator to any point in the loop and add resistance as necessary.
The Field Communicator must be connected across a resistance of
250–600
Ω
.
Field Communicator connection to local HART loop
Figure B-2:
A. Field Communicator
B.
250–600
Ω
resistance
3.
To connect to a point in the HART multidrop network, attach the leads from the
Field Communicator to any point on the network.