Concentration measurement HART process variables
(continued)
Table 6-23:
Process variable
Primary Varia-
ble (PV)
Secondary
Variable (SV)
Third Variable
(TV)
Fourth Varia-
ble (QV )
CM Net Volume Inventory
✓
CM Net Volume Total
✓
CM Specific Gravity
✓
✓
✓
CM Standard Volume Flow
✓
✓
✓
✓
CM Standard Volume Inventory
✓
CM Standard Volume Total
✓
Fuel consumption HART process variables
Table 6-24:
Process variable
Primary Varia-
ble (PV)
Secondary
Variable (SV)
Third Variable
(TV)
Fourth Varia-
ble (QV )
Differential mass flow
✓
✓
✓
✓
Differential mass inventory
✓
Differential mass total
✓
PVR-only HART process variables
Table 6-25:
Process variable
Primary Varia-
ble (PV)
Secondary
Variable (SV)
Third Variable
(TV)
Fourth Varia-
ble (QV )
Corrected Oil Flow
✓
✓
✓
Corrected Oil Total
✓
Corrected Water Cut
✓
✓
✓
Corrected Water Flow
✓
✓
✓
Corrected Water Total
✓
Density of Oil @ Line Fixd degAPI
✓
Density of Oil @ Line Fixd SGU
✓
Oil Total @ Line
✓
Shrinkage Factor Corrected Oil Flow @ 60F
✓
✓
✓
Shrinkage Factor Corrected Oil Flow @ Line
✓
✓
✓
Shrinkage Factor Corrected Oil Total @ 60F
✓
Shrinkage Factor Corrected Oil Total @ Line
✓
Shrinkage Factor Corrected Total of Mix @ 60F
✓
Shrinkage Factor Corrected Volume Of Mix @ 60F
✓
✓
✓
Uncorrected Oil Flow
✓
✓
✓
Uncorrected Water Cut
✓
✓
✓
Uncorrected Water Flow
✓
✓
✓
Integrate the meter with the control system
Configuration and Use Manual
107
Summary of Contents for Micro Motion 2500
Page 8: ...Contents vi Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 10: ...Getting started 2 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 18: ...Quick start 10 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 237: ...NE 53 history Configuration and Use Manual 229 ...