1 Safety instructions

Electrical devices may only be mounted and connected by electrically skilled
persons.

Serious injuries, fire or property damage possible. Please read and follow manual fully.

Keep button cells out of reach of children! If button cells are swallowed, get medical help
immediately.

Risk of explosion! Do not throw batteries into fire.

Risk of explosion! Do not recharge batteries.

The radio communication takes place via a non-exclusively available transmission path,
and is therefore not suitable for safety-related applications, such as emergency stop and
emergency call.

These instructions are an integral part of the product, and must remain with the end
customer.

2 Device components

Figure 1: 4-gang radio wall transmitter module

(1) Base plate
(2) Fastening screws for the base plate
(3) Design frame
(4) Wall transmitter module
(5) Cover
(6) Fastening screws for the wall transmitter module

1/10

32595513
J0082595513

22.03.2017

Summary of Contents for FMx5001M Series

Page 1: ...ldren If button cells are swallowed get medical help immediately Risk of explosion Do not throw batteries into fire Risk of explosion Do not recharge batteries The radio communication takes place via a non exclusively available transmission path and is therefore not suitable for safety related applications such as emergency stop and emergency call These instructions are an integral part of the pro...

Page 2: ...er list is in the Internet in the documentation for this device Supplementary function with eNet server Update of the device software 4 Operation i When operating with the eNet Server operation and signalling could vary from what is described here Function of LED in operation As soon as a button is pressed or released the transmission LED 9 signals radio transmission LED lights up for 2 seconds Th...

Page 3: ...utton for longer than 0 4 seconds Operating blind o Moving the Venetian blind Press the button for longer than 1 second o Stopping the Venetian blind or adjusting the slats Press the button for less than 1 second Operating push button actuator o Press the left or right button of a channel The load is switched on for the duration of the button press i The maximum actuation length is 60 seconds Reca...

Page 4: ...e sources of interference e g metallic surfaces microwave ovens hi fi and TV systems ballasts or transformers o Change the battery see chapter Changing the battery o Screw or glue the base plate 1 to an even surface The TOP OBEN label has to be at the top o Position the design frame 3 on the base plate o Screw wall transmitter module 4 to base plate i Screwing the screws too tightly could impair f...

Page 5: ...to the positive contact of the battery holder 14 Observe polarity the positive pole of the battery must be at the top o Press gently on battery to snap it in o Snap on the cover 5 DANGER Electrical shock when live parts are touched Electrical shocks can be fatal During commissioning cover the parts carrying voltage on radio transmitters and actuators and in their surrounding area Connecting channe...

Page 6: ... radio faults i If the status LED of the actuator flashes 3 times at 1 second intervals for approx 5 seconds then the programming operation was not successful All the memory locations in the actuator or radio transmitter are occupied i Press the top left 10 and bottom right 11 button once again simultaneously for longer than 4 seconds to terminate the programming mode earlier i The All Off button ...

Page 7: ... again simultaneously for longer than 4 seconds to terminate the programming mode earlier Disconnecting connection to an actuator o Carry out the same steps as when connecting see the chapter Connecting channel button to radio actuator or scene button to radio actuator The status LED of the actuator flashes quickly for 5 seconds The actuator is disconnected from the radio transmitter The actuator ...

Page 8: ...on LED flashes faster o Release buttons and press the top left 10 and bottom right 11 buttons simultaneously once again The transmission LED flashes more slowly for approx 5 seconds The wall transmitter is reset to default setting All the buttons are set as channel buttons 6 Appendix Remove empty batteries immediately and dispose of in an environmentally friendly manner Do not throw batteries into...

Page 9: ...tting Extended channel settings Parameter name Setting options Basic setting Explanations Manual commissioning On Off Basic setting On Blocks manual commissioning for the device channel Note In the Off setting the device cannot be reset to the factory setting Local Operation On Off Basic setting On Blocks the device channel for local operation 6 3 Troubleshooting After a brief button press the tra...

Page 10: ...will again be polled on button actuation Actuate the transmitter again after a short waiting time normally a few seconds Reduce the number of actuations Reduce the number of actuators connected to the transmitter 6 4 Accessories Cover kit 1 gang Art No 501TSA Cover kit 2 gang Art No 502TSA Cover kit 3 gang Art No 503TSA Cover kit 4 gang Art No 504TSA 6 5 Conformity Albrecht Jung GmbH Co KG hereby ...