11.2.5
Schedule automatic execution of the SMV test
You can set up and run a single test at a user-defined future time. You can also set up and
run tests on a regular schedule.
Manage scheduled test execution using ProLink III
1.
Choose Device Tools > Diagnostics > Meter Verification > Schedule Meter
Verification.
2.
To schedule a single test or the first test in recurring execution, specify a value for
Hours Until Next Run.
3.
To schedule recurring execution, specify a value for Hours Between Recurring Runs.
4.
To disable scheduled execution:
•
To disable execution of a single scheduled test, set Hours Until Next Run to 0.
•
To disable recurring execution, set Hours Between Recurring Runs to 0.
•
To disable all scheduled execution, click Disable Scheduled Execution.
Manage scheduled test execution using the
Field Communicator
1.
Navigate to the Smart Meter Verification menu:
•
Overview > Shortcuts > Meter Verification
•
Service Tools > Maintenance > Routine Maintenance > Meter Verification
2.
Choose Automatic Verification.
3.
To schedule a single test or the first test in recurring execution, specify a value for
Hrs Until Next Run.
4.
To schedule recurring execution, specify a value for Set Recurring Hours.
5.
To disable scheduled execution:
•
To disable execution of a single scheduled test, set Hrs Until Next Run to 0.
•
To disable recurring execution, set Set Recurring Hours to 0.
•
To disable all scheduled execution, choose Turn Off Schedule.
11.3
Use PVR, TBR, and TMR
For detailed information about Production Volume Reconciliation (PVR), Transient Mist
Remediation (TMR), and Transient Bubble Remediation (TBR), see the
Micro Motion
®
Oil
and Gas Production Applications
manual.
Restriction
PVR, TBR, and TMR are available only with a transmitter that is ordered with one of these software
options:
Measurement support
Configuration and Use Manual
147
Summary of Contents for Micro Motion 2500
Page 8: ...Contents vi Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 10: ...Getting started 2 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 18: ...Quick start 10 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 237: ...NE 53 history Configuration and Use Manual 229 ...