Option
Setup
A value written by
digital communica-
tions
a. Choose Online > Configure > Manual Setup > Measurements >
External Pressure/Temperature > Temperature .
b. Set External Temperature to
Enabled
.
c. Perform the necessary host programming and communications
setup to write temperature data to the transmitter at appropri-
ate intervals.
Note
If the Weights & Measures application is implemented and the trans-
mitter is secured, digital communications cannot be used to write
temperature or pressure data to the transmitter.
4.7.4
API tables supported by the petroleum measurement
application
The API tables listed here are supported by the petroleum measurement application.
Table
name
Process fluid
CTL source data
Reference temperature Density unit
5A
Generalized crude and
JP4
Observed density and
observed temperature
60 °F (non-configurable) Degrees API
Range: 0 to 100
5B
Generalized products
Observed density and
observed temperature
60 °F (non-configurable) Degrees API
Range: 0 to 85
5D
Lubricating oils
Observed density and
observed temperature
60 °F (non-configurable) Degrees API
Range:
−
10 to +45
6C
Liquids with a constant
density base or known
thermal expansion coef-
ficient
User-supplied reference
density (or thermal ex-
pansion coefficient) and
observed temperature
60 °F (non-configurable) Degrees API
23A
Generalized crude and
JP4
Observed density and
observed temperature
60 °F (non-configurable) Relative density
Range: 0.6110 to 1.0760
23B
Generalized products
Observed density and
observed temperature
60 °F (non-configurable) Relative density
Range: 0.6535 to 1.0760
23D
Lubricating oils
Observed density and
observed temperature
60 °F (non-configurable) Relative density
Range: 0.8520 to 1.1640
24C
Liquids with a constant
density base or known
thermal expansion coef-
ficient
User-supplied reference
density (or thermal ex-
pansion coefficient) and
observed temperature
60 °F (non-configurable) Relative density
Configure process measurement
Configuration and Use Manual
49
Summary of Contents for Micro Motion 2500
Page 8: ...Contents vi Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 10: ...Getting started 2 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 18: ...Quick start 10 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Page 237: ...NE 53 history Configuration and Use Manual 229 ...