5.2 Decommissioning
5.2.1
Dismantling
L
IFE HAZARD
!
The installation must be completely dead before
dismantling.
Personal protection equipment
Safety goggles
Protective clothing and footwear
Removing the main spring, 630 A panels
L
IFE HAZARD
!
The installation must be disconnected from the
mains.
Note:
The description refers to figure 1 in chapter 6.1.1.
1. Switch the installation off
(see chapter 4.2.2/4.2.3).
2.
• Place the operating handle on the
operating shaft of the switch.
Turn the operating shaft a quarter turn clockwise
and keep it in this position.
3. Insert an L profile in the slot which comes free under
strip G of the main spring (figure 1).
4. Turn the operating shaft back.
5. Remove the pin (X) and remove the main spring
completely from the mechanism.
D
ANGER WARNING
The main spring is still tensioned. It must first
be clamped. After that, the interlocks can be
removed and the spring carefully released.
The user is himself responsible for the safe
execution of this procedure.
Removing the main spring, 1250 A panels
The main spring of 1250 A panels may only be removed by
or under the supervision of Eaton.
5.2.2
disposal
Switchgear should be disposed of in an environmentally
responsible manner.
Substances and materials arising from dismantling should
be destroyed, re-used or disposed of in accordance with
the regulations and requirements currently in force.
A list of the materials used is available from Eaton.
1.
Summary of Contents for SVS/12
Page 133: ...SVS 12 994 530 G01 02 133 9 2 Voltage detecting system Wega 1 2...
Page 134: ...SVS 12 134 994 530 G01 02...
Page 135: ...SVS 12 994 530 G01 02 135...
Page 136: ...SVS 12 136 994 530 G01 02...
Page 137: ...SVS 12 994 530 G01 02 137 9 3 Phase monitor Orion 3 0...
Page 138: ...SVS 12 138 994 530 G01 02...