P
ar. No.
#
P
a
rame
ter de
script
ion
De
fa
ult
va
lue
4-
set-
up
Chang
e
during
o
p
er-
ation
Conve
r-
sion
inde
x
Type
5-
0*
Di
git
al I/
O mode
5-
0
0
Digi
ta
l
I/O
Mode
[0] P
N
P -
Active a
t 24V
A
ll
se
t-u
ps
FALSE
-
U
in
t8
5-0
1
Te
rm
ina
l 27 Mode
[0] I
n
put
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
5-0
2
Term
inal
29
Mo
de
[0] I
n
put
A
ll
set-
u
p
s
T
R
U
E
-
Ui
n
t8
5-
1* Di
git
al
In
pu
ts
5-1
0
Term
inal
18 Di
g
ital I
n
put
[8]
S
tart
A
ll set-
u
p
s
T
R
U
E
-
Ui
n
t8
5-1
1
Term
inal
19 Di
g
ital I
n
put
[0
] No
op
era
tio
n
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
5-1
2
Term
inal
27 Di
g
ital I
n
put
null
A
ll set-
u
p
s
T
R
U
E
-
Ui
n
t8
5-1
3
Term
inal
29 Di
g
ital I
n
put
[0
] No
op
era
tio
n
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
5-1
4
Term
inal
32 Di
g
ital I
n
put
[0] N
o
o
p
e
rati
on
A
ll set-
u
p
s
T
R
U
E
-
Ui
n
t8
5-1
5
Term
inal
33 Di
g
ital I
n
put
[0
] No
op
era
tio
n
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
5-1
6
Term
inal
X
30/
2 Di
gi
tal
I
n
p
u
t
[0] N
o
o
p
e
rati
on
A
ll set-
u
p
s
T
R
U
E
-
Ui
n
t8
5-1
7
Term
inal
X
30/
3 Di
gi
tal
I
n
p
u
t
[0
] No
op
era
tio
n
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
5-1
8
Term
inal
X
30/
4 Di
gi
tal
I
n
p
u
t
[0] N
o
o
p
e
rati
on
A
ll set-
u
p
s
T
R
U
E
-
Ui
n
t8
5-
3* Di
git
al Outp
ut
s
5
-30
Te
rmi
na
l 2
7
Di
git
al
O
u
tp
ut
[0
]
No
op
era
tio
n
Al
l
se
t-u
ps
TRU
E
-
U
in
t8
5-3
1
Term
inal
29 Dig
it
al
Output
[0
] No
op
era
tio
n
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
5-3
2
Term
X
30/
6 D
ig
i
Out
(MCB 10
1)
[0
] N
o
o
p
e
rati
on
A
ll set-
u
p
s
T
R
U
E
-
Ui
n
t8
5-3
3
Term
X
30/
7 D
ig
i
Out
(MCB 10
1)
[0
] No
op
era
tio
n
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
5-
4* Rel
ays
5-4
0
Funct
io
n
R
e
lay
null
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
5
-41
O
n
De
la
y,
Rel
ay
0.0
1 s
A
ll
set-
u
p
s
T
R
U
E
-2
U
int16
5-4
2
O
ff Delay,
Re
la
y
0.0
1 s
Al
l s
e
t-
u
p
s
TRU
E
-2
Ui
nt1
6
5-
5* P
u
lse
In
pu
t
5-5
0
Te
rm
. 29 Lo
w Fre
que
ncy
1
00 Hz
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt3
2
5-5
1
Term
. 29 Hig
h Freq
uency
1
00 Hz
A
ll
set-
u
p
s
T
R
U
E
0
U
int32
5-5
2
Te
rm
. 29 Lo
w R
e
f.
/Fe
edb
.
Va
lue
0.000 N/
A
Al
l s
e
t-
u
p
s
TRU
E
-3
Int32
5-5
3
Term
. 29 Hig
h
R
e
f./Fe
ed
b
.
Value
1
00.000 N/
A
A
ll
set-
u
p
s
T
R
U
E
-3
Int32
5-5
4
Pu
lse Filter Time Consta
nt #29
1
00 ms
Al
l s
e
t-
u
p
s
FALSE
-3
Ui
nt1
6
5-5
5
Term
. 33 Low
Freq
uency
1
00 Hz
A
ll
set-
u
p
s
T
R
U
E
0
U
int32
5-5
6
Term
. 33 High Frequency
1
00 Hz
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt3
2
5-5
7
Term
. 33 Low
Re
f./
Fee
d
b
.
V
a
lu
e
0
.000 N/
A
A
ll
set-
u
p
s
T
R
U
E
-3
Int32
5-5
8
Te
rm.
3
3
Hi
gh
Re
f./
Fee
db.
V
a
lu
e
1
00.000 N/
A
Al
l s
e
t-
u
p
s
TRU
E
-3
Int32
5-5
9
P
u
lse Fi
lter Ti
me Constant
#3
3
1
00
ms
A
ll set-u
p
s
FALSE
-3
U
int16
5-
6* Pu
ls
e Ou
tp
ut
5
-60
Te
rmi
na
l 2
7
P
u
lse
O
u
tpu
t
Vari
ab
le
[0
]
No
op
era
tio
n
Al
l
se
t-u
ps
TRU
E
-
U
in
t8
5-6
2
Pu
lse
O
u
tput
Max Fre
q #27
5000 Hz
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt3
2
5
-63
Te
rmi
na
l 2
9
P
u
lse
O
u
tpu
t
Vari
ab
le
[0
]
No
op
era
tio
n
Al
l
se
t-u
ps
TRU
E
-
U
in
t8
5-6
5
Pu
lse
O
u
tput
Max Fre
q #29
5000 Hz
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt3
2
5-6
6
T
erm
inal
X30
/6
P
u
lse
Output V
a
ri
ab
le
[0
] N
o
o
p
e
rati
on
A
ll set-
up
s
T
R
U
E
-
Ui
nt8
5-6
8
Pu
lse
O
u
tput
Max Fre
q #X30/6
5000 Hz
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt3
2
5-
9* Bus Controll
ed
5-9
0
Digita
l &
R
e
lay Bus Cont
rol
0 N/A
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt3
2
5-9
3
P
u
lse
Out #27 Bus Control
0.00 %
A
ll
set-u
p
s
TRUE
-2
N2
5-9
4
Pu
lse
O
u
t #27 Timeout
Pre
set
0.
00 %
1 set-up
TRU
E
-2
Ui
nt1
6
5-9
5
P
u
lse
Out #29 Bus Control
0.00 %
A
ll
set-u
p
s
TRUE
-2
N2
5-9
6
Pu
lse
O
u
t #29 Timeout
Pre
set
0.
00 %
1 set-up
TRU
E
-2
Ui
nt1
6
5-9
7
P
u
lse
Out #X30
/6 Bus
C
o
ntrol
0.00 %
A
ll
set-u
p
s
TR
UE
-2
N2
5-9
8
Pu
ls
e
Out #X30
/6 Tim
e
out
Pre
set
0.
00 %
1 set-up
TRU
E
-2
Ui
nt1
6
3.1.7
Digital In/
Out 5-**
VLT
p
Automation VT Drive FC322
Programming Guide
3 Parameter Lists
MG.20.W1.22 - VLT
p
is a registered Danfoss trademark
275
3
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20772-Danfoss-131X8135-VLT-Automation-VT-Drive-VFD-FC322-230V-5-HP.aspx