P
ar. No.
#
P
a
rame
ter de
script
ion
De
fa
ult
va
lue
4-
set-
up
Chang
e
during
o
p
er-
ation
Conve
r-
sion
inde
x
Type
26
-0* An
alog I/
O Mode
26-
00
Term
inal
X
42/
1 Mo
d
e
[1]
V
o
lt
ag
e
A
ll set-
u
p
s
T
R
U
E
-
Ui
n
t8
26-
01
Term
inal
X
42/
3 Mo
d
e
[1] V
o
lt
ag
e
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
26-
02
Term
inal
X
42/
5 Mo
d
e
[1]
V
o
lt
ag
e
A
ll set-
u
p
s
T
R
U
E
-
Ui
n
t8
26
-1* An
alog In
pu
t X42/
1
26-
10
Term
inal
X42
/1 Lo
w
Vo
lt
ag
e
0
.0
7
V
A
ll set-
u
p
s
T
R
U
E
-2
Int16
26-
11
Te
rm
ina
l
X42/1 H
igh Volt
age
10
.0
0
V
Al
l s
e
t-
u
p
s
TRU
E
-2
Int16
26-
14
Term
. X42
/1 Lo
w
R
e
f./F
ee
db
.
Val
u
e
0.000 N/
A
A
ll
set-
u
p
s
T
R
U
E
-3
Int32
26-
15
Te
rm.
X
4
2/
1
H
ig
h
Ref
./Fe
ed
b.
Va
lu
e
1
00.000 N/
A
Al
l s
e
t-
u
p
s
TRU
E
-3
Int32
26-
16
Term
. X42
/1 Fi
lte
r
Ti
me Constan
t
0
.001 s
A
ll
set-u
p
s
T
R
U
E
-3
U
int16
26-
17
Term
. X42
/1 Live
Zero
[1
] E
n
ab
led
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
26
-2* An
alog In
pu
t X42/
3
26-
20
Te
rm
ina
l
X42/3 Low Volt
age
0.0
7 V
Al
l s
e
t-
u
p
s
TRU
E
-2
Int16
26-
21
Term
inal
X42
/3 H
ig
h
Vo
lt
ag
e
1
0.0
0 V
A
ll set-
u
p
s
T
R
U
E
-2
Int16
26-
24
Te
rm.
X
4
2/
3
Low
Ref
./
Fe
ed
b.
V
a
lu
e
0.000 N/
A
Al
l s
e
t-
u
p
s
TRU
E
-3
Int32
26-
25
Term
. X42
/3 Hi
gh
R
e
f.
/Fee
db
.
V
a
lu
e
1
00.
000 N/
A
A
ll
set-
u
p
s
T
R
U
E
-3
Int32
26-
26
Te
rm
. X42/3 Filter
Time
Co
nstan
t
0.
001 s
Al
l s
e
t-
u
p
s
TRU
E
-3
Ui
nt1
6
26-
27
Term
. X42
/3 Live
Zero
[1
] Enabl
e
d
A
ll
set-
u
p
s
T
R
U
E
-
Ui
n
t8
26
-3* An
alog In
pu
t X42/
5
26-
30
Term
inal
X42
/5 Lo
w
Vo
lt
ag
e
0
.0
7
V
A
ll set-
u
p
s
T
R
U
E
-2
Int16
26-
31
Te
rm
ina
l
X42/5 H
igh Volt
age
10
.0
0
V
Al
l s
e
t-
u
p
s
TRU
E
-2
Int16
26-
34
Term
. X42
/5 Lo
w
R
e
f./F
ee
db
.
Val
u
e
0.000 N/
A
A
ll
set-
u
p
s
T
R
U
E
-3
Int32
26-
35
Te
rm.
X
4
2/
5
H
ig
h
Ref
./Fe
ed
b.
Va
lu
e
1
00.000 N/
A
Al
l s
e
t-
u
p
s
TRU
E
-3
Int32
26-
36
Term
. X42
/5 Fi
lte
r
Ti
me Constan
t
0
.001 s
A
ll
set-u
p
s
T
R
U
E
-3
U
int16
26-
37
Term
. X42
/5 Live
Zero
[1
] E
n
ab
led
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
26
-4* An
alog Out
X42
/7
26-
40
Term
ina
l X42/7 Outpu
t
[0
] No
op
era
tio
n
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
26-
41
Term
inal
X42
/7 Mi
n.
Scale
0.00 %
A
ll
set-
u
p
s
T
R
U
E
-2
Int16
26-
42
Term
inal
X42
/7 Max.
Scal
e
100.
00 %
Al
l s
e
t-
u
p
s
TRU
E
-2
Int16
26-43
Term
inal
X42
/7 Bus
Cont
rol
0.00 %
A
ll
set-u
p
s
TRUE
-2
N2
26-
44
Te
rm
ina
l
X42/7 Timeo
ut Pre
se
t
0.
00 %
1 set-up
TRU
E
-2
Ui
nt1
6
26
-5* An
alog Out
X42
/9
26-
50
Term
ina
l X42/9 Outpu
t
[0
] No
op
era
tio
n
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
26-
51
Term
inal
X42
/9 Mi
n.
Scale
0.00 %
A
ll
set-
u
p
s
T
R
U
E
-2
Int16
26-
52
Term
inal
X42
/9 Max.
Scal
e
100.
00 %
Al
l s
e
t-
u
p
s
TRU
E
-2
Int16
26-53
Term
inal
X42
/9 Bus
Cont
rol
0.00 %
A
ll
set-u
p
s
TRUE
-2
N2
26-
54
Te
rm
ina
l
X42/9 Timeo
ut Pre
se
t
0.
00 %
1 set-up
TRU
E
-2
Ui
nt1
6
26
-6* An
alog Out
X42
/11
26-
60
Te
rm
ina
l X42/11
Output
[0
] No
op
era
tio
n
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
26-
61
Term
inal
X42
/11
Mi
n. Scal
e
0
.00
%
A
ll set-
u
p
s
T
R
U
E
-2
Int16
26-
62
Te
rm
ina
l
X42/11 Max. Scale
100.
00 %
Al
l s
e
t-
u
p
s
TRU
E
-2
Int16
26-63
Term
inal
X42
/11
Bus Contr
ol
0.00
%
A
ll set-u
p
s
T
R
U
E
-2
N
2
26-
64
Te
rm
ina
l
X42/11 Timeou
t Prese
t
0.
00 %
1 set-up
TRU
E
-2
Ui
nt1
6
3.1.2
2
Analog
I/O Option MCB
1
09 26-*
*
VLT
p
Automation VT Drive FC322
Programming Guide
3 Parameter Lists
MG.20.W1.22 - VLT
p
is a registered Danfoss trademark
295
3
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20772-Danfoss-131X8135-VLT-Automation-VT-Drive-VFD-FC322-230V-5-HP.aspx