P
ar. No.
#
P
a
rame
ter de
script
ion
De
fa
ult
va
lue
4-
set-
up
Chang
e
during
o
p
er-
ation
Conve
r-
sion
inde
x
Type
14
-0* In
ve
rt
e
r
Sw
it
c
h
in
g
14-00
Swi
tch
in
g
Pattern
n
u
ll
A
ll s
e
t-
up
s
T
R
U
E
-
Ui
nt
8
14-
01
Sw
itch
ing Frequ
ency
null
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
14-
03
Ove
rmod
ul
atio
n
[1] On
A
ll
set-u
p
s
FALSE
-
U
in
t8
14-
04
PW
M R
a
nd
om
[0] Off
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
14
-1* Mains
On/Off
14-
10
Mains Fa
ilure
[0] No fu
ncti
on
Al
l s
e
t-
u
p
s
FALSE
-
Ui
nt8
14-11
Mains Voltag
e at Mains Faul
t
S
R
A
ll
set-u
p
s
TRUE
0
U
int16
14-
12
Funct
ion
at
Mains Imba
lan
ce
[3
] Der
ate
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
14
-2* Re
set
Fun
ct
io
n
s
14-
20
Re
set Mod
e
[1
0] Aut
omatic reset
x
10
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
14-21
Automatic Restart
Ti
me
10 s
A
ll
set-u
p
s
TRUE
0
U
int16
14-
22
Operation Mode
[0
] Normal
operat
io
n
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
14-23
Typecod
e Sett
in
g
null
2 se
t-
ups
FALSE
-
U
in
t8
14-
25
Trip De
la
y a
t
Torq
ue
Lim
it
60 s
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt8
14-26
Trip
Del
a
y
at
I
n
verter Faul
t
S
R
A
ll
set-u
p
s
TRUE
0
U
in
t8
14-
28
Pro
duction Sett
in
gs
[0] No
acti
on
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
14-
29
Servi
ce C
o
d
e
0 N/A
A
ll
set-u
ps
TRUE
0
Int32
14
-3* Cu
rr
en
t Li
mit
Ctr
l.
14-30
Current Li
m
Ctrl, Proportional
Gain
100
%
A
ll set-u
p
s
FALSE
0
U
int16
14-
31
Curre
nt Lim
Ctrl, Int
egra
tio
n
Time
0.
020 s
Al
l s
e
t-
u
p
s
FALSE
-3
Ui
nt1
6
14-32
Current Li
m
Ctrl, Fil
ter Ti
me
27.0
ms
A
ll set-u
p
s
FALSE
-4
U
int16
14
-4* En
er
gy Opti
misi
ng
14-
40
VT L
e
vel
66
%
A
ll set-u
p
s
FALSE
0
U
in
t8
14-
41
A
E
O M
ini
mu
m M
a
gnet
isat
ion
SR
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt8
14-
42
Mi
n
imum AEO
Freq
uency
10 Hz
A
ll
set-
u
p
s
T
R
U
E
0
Ui
n
t8
14-
43
Moto
r Cosphi
SR
Al
l s
e
t-
u
p
s
TRU
E
-2
Ui
nt1
6
14
-5* Env
ir
onme
n
t
14-
50
RFI
Filter
[1] On
1 set-up
FALSE
-
Ui
nt8
14-52
Fan Control
[0] Auto
A
ll
set-u
p
s
TRUE
-
U
in
t8
14-
53
Fa
n M
o
ni
to
r
[1
] Warning
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
14-55
Outp
u
t Fi
lter
[0
] No Fi
lter
1 set-up
FALSE
-
U
in
t8
14-
59
Actual
Numb
e
r o
f I
n
verter
Units
SR
1 set-up
FALSE
0
Ui
nt8
14
-6* Auto
Der
ate
14-
60
Funct
ion
at
Ove
r Tempe
rature
[1
] Der
ate
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
1
4
-6
1
Funct
ion
at
I
n
ve
rter O
v
er
loa
d
[1]
Der
ate
Al
l
se
t-u
ps
TRU
E
-
U
in
t8
14-
62
Inv. Ov
erlo
ad Dera
te
Curre
nt
95
%
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt1
6
14
-8* Opt
ions
14-
80
O
p
ti
on Supp
lie
d by E
x
te
rna
l 2
4
V
DC
[0
] No
2 set-up
s
FALSE
-
Ui
nt8
3.1.1
3
Special Functions 14-*
*
VLT
p
Automation VT Drive FC322
Programming Guide
3 Parameter Lists
MG.20.W1.22 - VLT
p
is a registered Danfoss trademark
281
3
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20772-Danfoss-131X8135-VLT-Automation-VT-Drive-VFD-FC322-230V-5-HP.aspx