5-57 Term. 33 Low Ref./Feedb. Value
Range:
Function:
0.000*
[-999999.999 - 999999.999 ]
Enter the low reference value [RPM] for the motor shaft speed. This is also the low feedback value,
see also par. 5-52
Term. 29 Low Ref./Feedb. Value
.
5-58 Term. 33 High Ref./Feedb. Value
Range:
Function:
100.000*
[-999999.999 - 999999.999 ]
Enter the high reference value [RPM] for the motor shaft speed. See also par. 5-53
Term. 29 High
Ref./Feedb. Value
.
5-59 Pulse Filter Time Constant #33
Range:
Function:
100 ms*
[1 - 1000 ms]
Enter the pulse filter time constant. The low-pass filter reduces the influence on and dampens os-
cillations on the feedback signal from the control.
This is an advantage, e.g. if there is a great amount on noise in the system. This parameter cannot
be adjusted while the motor is running.
2.7.7 5-6* Pulse Outputs
Parameters for configuring the scaling and output functions of pulse outputs. The pulse outputs are designated to terminals 27 or 29. Select terminal 27
output in par. 5-01 and terminal 29 output in par. 5-02.
Options for readout output variables:
[0] *
No operation
[45]
Bus ctrl.
[48]
Bus ctrl., timeout
[100]
Output frequency
[101]
Reference
[102]
Feedback
[103]
Motor current
2 Parameter Description
VLT
p
Automation VT Drive FC322
Programming Guide
94
MG.20.W1.22 - VLT