P
ar. No.
#
P
a
rame
ter de
script
ion
De
fa
ult
va
lue
4-
set-
up
Chang
e
during
o
p
er-
ation
Conve
r-
sion
inde
x
Type
1-
0* General Set
ti
ngs
1-0
0
Con
fi
guration Mode
n
u
ll
A
ll s
e
t-
up
s
T
R
U
E
-
Ui
nt
8
1-0
1
Moto
r Contro
l Princi
ple
null
Al
l s
e
t-
u
p
s
FALSE
-
Ui
nt8
1-
0
3
Tor
que
Chara
cteristics
[3] Aut
o Ene
rgy Optim.
VT
A
ll
se
t-u
ps
TRUE
-
U
in
t8
1-
1* Mot
or
Se
le
ct
ion
1-
1
0
Moto
r Con
struction
[0
] Asynchron
A
ll
set-u
ps
FALSE
-
U
in
t8
1-
2* Mot
or
Dat
a
1-
20
Moto
r Po
we
r [kW]
SR
A
ll se
t-u
ps
FALSE
1
U
int32
1-2
1
Moto
r Po
we
r [HP]
SR
Al
l s
e
t-
u
p
s
FALSE
-2
Ui
nt3
2
1-2
2
M
otor V
o
ltage
SR
A
ll se
t-u
ps
FALSE
0
U
int16
1-2
3
Motor Frequen
cy
SR
Al
l s
e
t-
u
p
s
FALSE
0
Ui
nt1
6
1-
2
4
Moto
r Curren
t
SR
A
ll se
t-u
ps
FALSE
-2
Uint32
1-2
5
Moto
r Nominal
Speed
SR
Al
l s
e
t-
u
p
s
FALSE
67
Ui
nt1
6
1-
2
8
Moto
r Ro
tat
io
n
Check
[0]
Off
A
ll
se
t-u
ps
FALSE
-
U
in
t8
1-2
9
Auto
matic Moto
r Ada
ptat
io
n
(AMA)
[0] Off
Al
l s
e
t-
u
p
s
FALSE
-
Ui
nt8
1-
3* Adv
. M
o
tor
Dat
a
1-3
0
St
ato
r R
e
sistance
(R
s)
SR
Al
l s
e
t-
u
p
s
FALSE
-4
Ui
nt3
2
1-
31
Ro
tor Resi
stan
ce
(
R
r)
SR
A
ll se
t-u
ps
FALSE
-4
Uint32
1-3
2
St
ator Rea
ct
ance (X
s)
SR
Al
l s
e
t-
u
p
s
FALSE
-4
Ui
nt3
2
1-
33
St
ato
r L
e
ak
age
Rea
ct
ance
(X1)
SR
A
ll
se
t-u
ps
FALSE
-4
Uint32
1-3
4
Ro
tor
Lea
kage
Rea
ctan
ce
(
X
2
)
SR
Al
l s
e
t-
u
p
s
FALSE
-4
Ui
nt3
2
1-
35
Main Re
acta
nce (Xh
)
SR
A
ll se
t-u
ps
FALSE
-4
Uint32
1-3
6
Iron Loss
R
e
sist
ance (Rfe
)
SR
Al
l s
e
t-
u
p
s
FALSE
-3
Ui
nt3
2
1-3
9
M
otor Poles
SR
A
ll se
t-u
ps
FALSE
0
U
in
t8
1-
5* Load I
n
d
e
p.
S
e
tt
ing
1-
50
Moto
r
Mag
netisation at Zer
o
Sp
eed
100 %
A
ll se
t-u
ps
TRU
E
0
Uint16
1-5
1
Mi
n
Speed Norm
a
l Magnetisi
n
g
[
R
PM]
SR
Al
l s
e
t-
u
p
s
TRU
E
67
Ui
nt1
6
1-5
2
M
in
Speed Normal
Magnetisi
n
g
[H
z]
SR
A
ll set-u
ps
TRUE
-1
Uint16
1-5
5
V/f Chara
cteristic -
V
SR
Al
l s
e
t-
u
p
s
TRU
E
-1
Ui
nt1
6
1-
5
6
V/f Chara
cteristic -
f
SR
A
ll set-u
ps
TRUE
-1
Uint16
1-
6*
Lo
ad De
pen. Set
ti
ng
1-
60
Lo
w
S
p
ee
d Loa
d Compen
sation
100 %
A
ll se
t-u
ps
TRUE
0
Int16
1-6
1
Hi
gh
S
p
ee
d Loa
d Compen
sati
on
100
%
Al
l s
e
t-
u
p
s
TRU
E
0
Int16
1-
6
2
Slip Compe
nsation
0 %
A
ll set-u
ps
TRUE
0
Int16
1-6
3
Slip
Compe
nsation Tim
e
Consta
nt
SR
Al
l s
e
t-
u
p
s
TRU
E
-2
Ui
nt1
6
1-6
4
R
esonance
Damp
ening
100
%
A
ll set-u
p
s
TR
UE
0
U
int16
1-6
5
Re
sona
nce D
a
mpen
ing Time
Co
nstan
t
5 ms
Al
l s
e
t-
u
p
s
TRU
E
-3
Ui
nt8
1-
7* Start
Adjust
ment
s
1-7
1
St
art Delay
0.
0 s
Al
l s
e
t-
u
p
s
TRU
E
-1
Ui
nt1
6
1-7
3
Flyi
ng S
tart
[0
] Di
sabl
ed
Al
l se
t-u
ps
FALSE
-
U
in
t8
1-7
4
St
art Spee
d
[RPM]
SR
Al
l s
e
t-
u
p
s
TRU
E
67
Ui
nt1
6
1-
7
5
St
art Speed [
H
z]
SR
A
ll set-u
ps
TRUE
-1
Uint16
1-7
6
St
art Curren
t
0.0
0 A
Al
l s
e
t-
u
p
s
TRU
E
-2
Ui
nt3
2
3.1.3
Load/Motor 1-**
3 Parameter Lists
VLT
p
Automation VT Drive FC322
Programming Guide
270
MG.20.W1.22 - VLT
p
is a registered Danfoss trademark
3
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com