P
ar. No.
#
P
a
rame
ter de
script
ion
De
fa
ult
va
lue
4-
set-
up
Chang
e
during
o
p
er-
ation
Conve
r-
sion
inde
x
Type
27
-0* Cont
rol &
Stat
us
27-01
Pu
m
p
Stat
us
[0] R
e
ad
y
A
ll
set-
u
p
s
T
R
U
E
-
Ui
n
t8
27-
02
Man
ual Pump
Co
ntrol
[0] No
Op
eratio
n
2 set-up
s
TRU
E
-
Ui
nt8
27-03
Curre
nt
Runtime Hours
0 h
A
ll
se
t-u
ps
TRUE
74
Uint32
27-
04
Pu
m
p
Tot
al Lif
etime Hours
0 h
Al
l s
e
t-
u
p
s
TRU
E
74
Ui
nt3
2
27
-1* Conf
igur
ati
on
27-
10
Casca
de Con
trolle
r
[0
] Di
sabl
ed
2 set-up
s
FALSE
-
Ui
nt8
27-11
Numb
er Of
Dri
v
e
s
1 N/A
2 set-ups
FALSE
0
U
in
t8
27-
12
Number Of
Pumps
SR
2 set-up
s
FALSE
0
Ui
nt8
27-14
Pu
m
p
C
a
p
a
ci
ty
100
%
2
set-ups
FALSE
0
U
int16
27-
16
R
u
ntim
e Balan
cing
[0
]
Balanced Priority 1
2 set-up
s
TRU
E
-
Ui
nt8
27-17
Motor Starters
[0
] D
irect Onl
ine
2
set-up
s
F
ALSE
-
U
in
t8
27-
18
Spi
n Ti
me
fo
r U
n
use
d
P
u
m
p
s
SR
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt1
6
27-19
Reset
Curren
t Runtim
e Hou
rs
[0] Do
not
reset
A
ll
set-u
ps
TRUE
-
Uin
t8
27
-2* B
a
n
d
wi
dth
S
e
tt
in
gs
27-
20
Normal
O
p
erat
in
g
Rang
e
S
R
A
ll set-
u
p
s
T
R
U
E
0
Ui
n
t8
27-
21
Override
L
imit
100
%
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt8
2
7
-2
2
Fi
xe
d Sp
ee
d O
n
ly
O
p
e
rati
ng
R
a
nge
SR
Al
l
se
t-u
ps
TRU
E
0
U
in
t8
27-
23
St
aging Delay
15 s
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt1
6
27-24
Dest
aging D
e
la
y
15 s
A
ll
set-
u
p
s
T
R
U
E
0
U
int16
27-
25
Override
Ho
ld
Time
10 s
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt1
6
27-27
Mi
n
Speed Destage Delay
SR
A
ll set-u
ps
TRUE
0
U
int16
27
-3* S
taging Spe
ed
27-
30
Au
to
T
u
ne
St
a
g
in
g
Sp
ee
d
s
[1
] En
a
b
le
d
A
ll
se
t-
up
s
T
R
U
E
-
Ui
nt
8
27-
31
St
age On Spee
d [RPM]
SR
Al
l s
e
t-
u
p
s
TRU
E
67
Ui
nt1
6
27-
32
St
ag
e On Sp
ee
d
[Hz]
SR
A
ll set-u
ps
TRUE
-1
Uint16
27-
33
St
age Off
Speed [RP
M
]
SR
Al
l s
e
t-
u
p
s
TRU
E
67
Ui
nt1
6
27-34
St
ag
e Off Spe
ed
[H
z]
SR
A
ll set-u
ps
TRUE
-1
Uint16
27
-4* S
taging Set
ti
ng
s
27-40
Auto Tun
e S
tag
ing
Setting
s
[0]
Disab
led
A
ll
set-u
p
s
TRUE
-
U
in
t8
27-
41
Ra
mp Down
De
la
y
10.
0 s
Al
l s
e
t-
u
p
s
TRU
E
-1
Ui
nt1
6
27-
42
R
a
mp
U
p
Del
ay
2.0 s
A
ll
set-
u
p
s
T
R
U
E
-1
U
int16
27-
43
St
aging Thre
shold
SR
Al
l s
e
t-
u
p
s
TRU
E
0
Ui
nt8
27-44
Dest
aging Threshol
d
S
R
A
ll s
e
t-
up
s
T
R
U
E
0
Ui
nt
8
27-
45
St
aging Spee
d [RPM]
0 R
P
M
Al
l s
e
t-
u
p
s
TRU
E
67
Ui
nt1
6
27-46
St
ag
ing
Sp
eed
[Hz]
0.0 Hz
A
ll
set-u
p
s
TRUE
-1
U
int16
27-
47
Dest
agi
ng Sp
eed
[
R
PM]
0 R
P
M
Al
l s
e
t-
u
p
s
TRU
E
67
Ui
nt1
6
27-48
Dest
aging Speed [
H
z]
0.0
Hz
A
ll set-u
ps
TRUE
-1
U
int16
27
-5* Alt
ernate
Set
ti
ngs
27-50
Auto
matic
Altern
ation
[0] Disabled
A
ll set-u
ps
FALSE
-
U
in
t8
27-
51
Alterna
ti
o
n
Event
null
Al
l s
e
t-
u
p
s
TRU
E
-
Ui
nt8
27-52
Alterna
ti
o
n
Time Interval
0
mi
n
A
ll
set-u
ps
TRUE
70
Uint16
27-
53
Alterna
tio
n Timer
Va
lu
e
0
mi
n
Al
l s
e
t-
u
p
s
TRU
E
70
Ui
nt1
6
27-54
Alternati
on At
Ti
me of
Day
[0]
Disab
led
A
ll
set-u
p
s
TRUE
-
U
in
t8
27-
55
Alterna
tio
n P
rede
fined
Time
SR
Al
l s
e
t-
u
p
s
TRU
E
0
Ti
m
e
Of
D
a
y-
Wo
D
a
te
27-56
Alterna
te Capa
ci
ty i
s <
0
%
A
ll set-u
ps
TRUE
0
U
in
t8
27-
58
Ru
n
Nex
t Pump Delay
0.
1 s
Al
l s
e
t-
u
p
s
TRU
E
-1
Ui
nt1
6
3.1.2
3
Cascade CTL
Option 2
7
-**
3 Parameter Lists
VLT
p
Automation VT Drive FC322
Programming Guide
296
MG.20.W1.22 - VLT
p
is a registered Danfoss trademark
3
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com