3-11 Jog Speed [Hz]
Range:
Function:
Application
dependent*
[Application dependant]
3-13 Reference Site
Option:
Function:
Select which reference site to activate.
[0] *
Linked to Hand / Auto
Use local reference when in Hand mode; or remote reference when in Auto mode.
[1]
Remote
Use remote reference in both Hand mode and Auto mode.
[2]
Local
Use local reference in both Hand mode and Auto mode.
NB!
When set to Local [2], the frequency converter will start with this setting again
following a 'power down'.
3-14 Preset Relative Reference
Range:
Function:
0.00 %*
[-100.00 - 100.00 %]
The actual reference, X, is increased or decreased with the percentage Y, set in par. 3-14
Preset
Relative Reference
. This results in the actual reference Z. Actual reference (X) is the sum of the
inputs selected in par. 3-15
Reference 1 Source
, par. 3-16
Reference 2 Source
, par. 3-17
Reference
3 Source
and par. 8-02
Control Source
.
2 Parameter Description
VLT
p
Automation VT Drive FC322
Programming Guide
56
MG.20.W1.22 - VLT
p
is a registered Danfoss trademark