71
6
When the replacement hard drive is recognized, the status LED will flash red and the message “Press FuncSW I31
New Disk x ready” will be displayed on the LCD panel.
7
Hold down the function button on the front of the TeraStation for 3 seconds until it beeps.
For RAID 1, 5, or 6:
The TeraStation will start rebuilding the RAID array automatically. After a few minutes, the message “RAID I18
ARRAY x Rebuilding” will be displayed until the array is rebuilt.
For RAID 51 or RAID 61:
The TeraStation will start rebuilding the RAID array automatically. After a few minutes, the message “RAID I18
ARRAY x Rebuilding” will be displayed until the array is rebuilt.
If more than 3 drives were replaced in a RAID 51 array, or if more than 4 drives were replaced in a RAID 61 array,
wait 10 minutes after I18 appears and navigate to
Drives
-
RAID
in Settings. Select the RAID array and check if
“Recover RAID Array” button is displayed. If so, select the drives that were not included in the RAID array and click
Recover RAID Array
.
For JBOD:
The drive will be formatted as an individual drive. Create a shared folder on the drive before use.