SYSTEM I10
TOO HOT !
A rise in the system temperature may have
exceeded the allowable safety value.
Move the TeraStation to a cool location. Do
not place objects in the area around the
TeraStation.
SYSTEM Error E11
Fan Failure
An error occurred in the fan speed.
Check that no foreign objects or dust are
clogging the fan. If any foreign objects or dust
are found, use a pair of tweezers, air duster,
or other tool to remove them. If the error is
displayed again, contact Buffalo technical
support for assistance.
SYSTEM Error E12
Cooling Failure
A rise in the system temperature may have
exceeded the allowable safety value.
Do not place objects in the area around the
TeraStation. Also, move the TeraStation to a
cool location.
RAID Arrayx E14
Can’t Mount
RAID array x cannot be mounted.
Run the RAID array disk check in Settings.
HDx Error E16
HDx Not Found
Unable to find hard drive x.
Hard drive x may be disconnected or may
have failed. After shutting down, reinstall the
hard drive.
HDx Error E22
HDx Can’t Mount
Mounting of hard drive x failed.
Format the hard drive. After formatting,
if the error still appears after rebooting,
replace the hard drive. If the error is displayed
again, contact Buffalo technical support for
assistance.
FailOver E27
LostBackupTarget
Unable to find the backup TeraStation.
In the main TeraStation’s settings, navigate to
Backup
-
Failover
to reconfigure the backup
TeraStation for failover.
HDx Broken E30
Replace the DISK
An error occurred, so hard drive x was
removed from the RAID array.
Replace hard drive x.
Status
After you change settings or format a hard drive, the current status is displayed on the LCD.
LCD Message
Description
Corrective Action
HDx Warning I11
Bad Sectors
The bad sectors in hard drive x may
have reached a dangerous level.
Replace hard drive x.
Operation I12
DEGRADE MODE
Operating in degraded mode.
-
RAID I13
ARRAYxFormatting
Formatting RAID array x.
-
RAID I14
ARRAYx Checking
Checking RAID array x.
-
RAID I15
ARRAYx Scanning
Examining the error status of RAID
array x.
Note:
Transfer speeds are slower
during the examination process.
-
RAID I16
ARRAYx Creating
Creating RAID array x.
-
RAID I17
ARRAYx Resyncing
Resynchronizing RAID array x.
Note:
Transfer speeds are slower
during resynchronization.
-
Summary of Contents for TeraStation 5000
Page 1: ...TeraStation 5000 User Manual www buffalotech com 35020018 04 2014 01...
Page 10: ...10 Chapter 1 Installation Diagrams TS5800D TS5600D TS5400D...
Page 69: ...69 4 Insert the new drive in the empty slot Slide the drive in with the locking mechanism open...
Page 70: ...70 5 Swing the lock back down until it clicks into place...