TCNM-AD/EX/SP Family Software Configuration Parameter Guide
90
NOTE
Before executing a Backup on a backup module make sure the Write Protection switch is set
to Unlocked.
If the backup module and the TCP/IP interface module are both installed, B&R is automatically
performed only on the backup module.
The TCP/IP interface module can execute B&R only with Network up and running (network
cable connected).
In the pictures above the Backup/Restore Dialog is shown:
the
Devices
window lists all of the available devices in the current configuration,
the
Backup Contents
window lists any previous device backups.
To perform a
Backup
:
1.
Press the Backup button (you will be warned that all previous backups will be overwritten)
2.
The Status window shows information as the backup procedure is being executed
To perform a
Restore
:
1.
Press the Restore button (you will be warned that all scanner configurations will be overwritten)
2.
The Status window shows information as the restore procedure is being executed
The
Restore
function also provides easy and secure Single Device Replacement:
1.
Remove the scanner to be replaced
2.
Connect the new scanner (make sure the new scanner has been previously set to default)
3.
Run the Restore procedure by pressing the Restore Button (see: Restore procedure)
To
Erase
any previous Backup:
1.
Press the Erase button
2.
All backups are deleted
The
Status
window shows the status of the backup procedure as it is being executed.
The following is a list of possible error messages:
Module not present
: backup module not mounted or not ready, or Search for TCNM-ACBB Backup Memory at Device
Startup parameter disabled
Unable to Read Backup State
: GeniusPlus is unable to get connected to the device
Backup function not allowed
: when device is in SMART-TEACH Menu mode
Failed! (Device not found)
: Master is unable to reach the addressed device
Failed! (Module is write protected)
: backup module Write Protection switch is set to Locked