Data Communication Settings
39
Code Identifier
A Code Identifier string can be included in the output message.
Possible selections are:
Selections:
Disable
no code identifier is included in the output message
Standard AIM ID
the AIM standard identifier is included in the output message
Custom
activates the Custom Code ID strings group allowing to define an identifier string for
each code symbology. The string will be included in the output message.
Standard Parameters
Header String
Headers (up to 128 bytes) can be defined and transmitted as a block preceding the barcode(s).
Selections: characters from
NUL
(00H) to
~
(7EH).
Code Position Tx
If enabled, the code position information is included in the output message. The scan line is divided into 256 physical
positions and therefore the code position value is transmitted in a fixed 3-digit decimal format separated by a Code
Field Separator before the Code Identifier field.
The code position is determined at the
center
of the label and is checked to be between the Min and Max parameters
specified in the configuration.
Code Direction Identifier Enable
If enabled (checked), the relative Code Direction Identifier string is included in the output message.
The forward, reverse and unknown direction strings, which indicate the scanning direction with respect to the code
direction, can be defined.
Forward Direction String
A Forward Direction string indicates that the current code has been scanned in the forward direction (scanning from
left to right). This string ("+" is the default value) can be customized by the user including up to 32 characters.
Selections:
characters from
NUL
(00H) to
~
(7EH).
Reverse Direction String
A Reverse Direction string indicates that the current code has been scanned in the reverse direction (scanning from
right to left). The string ("-" is the default value) can be customized by the user including up to 32 characters.
Selections:
characters from
NUL
(00H) to
~
(7EH).
Unknown Direction String
An Unknown Direction string indicates that it is not possible to determine the scanning direction of a code. This occurs
for the Pharmacode code which has no start/stop characters and for some code reconstruction reading conditions.
The string ("?" is the default value) can be customized by the user including up to 32 characters.
Selections:
characters from
NUL
(00H) to
~
(7EH).
Motor OFF
If checked, it allows sending the Motor OFF string whenever the motor is set OFF. The motor OFF condition can occur
either through the Scan Speed or Energy Saving parameters.
Motor OFF String
It defines the message string (up to 128 bytes) that will be sent whenever a Motor OFF condition exists. When the
Motor OFF condition occurs this string is sent instead of the Global No Read Message.
Selections:
characters from
NUL
(00H) to
~
(7EH).