Code Definition
13
activates the
Local No Read Strings
and the Local Multiple
Read Strings groups where setting respectively a Local No
Read String and a Local Multiple Read String for each
group label.
Do not use this option when working in single-label mode.
No Read String
It defines the string to be displayed in case of Global No Read Message. It is possible to select either an ASCII or HEX
value.
Multiple Read Message
This parameter is only available when the Code Combination is set to
Standard Multi Label
or
Logical Combination
.
When checked, this parameter allows the Multiple Read String to be sent if, during the reading phase, the scanner
reads more than the number of the expected barcodes set by the configuration parameters.
Multiple Read String
This parameter is only available when Multiple Read Message is enabled and the No Read Message selection is different
from Local No Read(s) String. It defines the string to be displayed in case of Multiple Read Message. It is possible to
select either the ASCII or HEX value. If
disabled
, the scanner transmits the first code read.
Associate Same Codes When Read By Different Scanners
This parameter is available only when the Code Combination parameter is set to
Code Collection
and the scanner
Topology Role is
Master
. If enabled, it allows transmitting all codes belonging to the same programmed Slot (same
symbology and content) but read by different scanners (including the Master) in a single instance.
Codes Different When Scan Gap Is Greater Than
This parameter is available only when the Code Combination parameter is set to
Code Collection
.
If the number of
scans performed between two consecutive codes read (by the Master or Stand Alone scanner) is greater than the
defined number, the codes will be considered as different.
The parameter set to 0 means the filter is disabled: when there is no scan gap all the consecutive codes read will be
considered as only one code.
Codes Different When Code Position Gap Is Greater Than
This parameter is available only when the Code Combination parameter is set to
Code Collection
. If the position gap
between two consecutive codes read (by the Master or Stand Alone scanner) on the same scan line is greater than the
defined gap number, the codes will be considered as different.
The parameter set to 0 means the filter is disabled: when there is no code position gap all the consecutive codes read
will be considered as only one code.