Reading Parameters
33
Triggered
If checked, it allows assigning a trigger through which the oscillating mirror can be activated to work in a second
reading zone according to the defined parameters.
Second Zone Trigger
This parameters defines the number of the input or the phase working as trigger.
Selections:
Phase
(available only when working in On Line operating mode)
Input 1
Input 2
Second Zone Trigger Level
This parameter allows setting the active state of the trigger. When the selected state is active, the oscillating mirror
starts working in the second reading zone according to the parameters set:
Selections:
Active Open
Active Closed
Second Zone Oscillating Mode
This parameter defines the oscillating mode of the scanner mirror to be used in the second reading zone:
Selections:
Fixed
the oscillating mirror deflects the scan line at a fixed angle of deflection (-
15°).
Continuous
the scan line is deflected according to the Second Zone Amplitude and
Second Zone Frequency settings.
Second Zone Amplitude (degrees)
This parameter is available only when working in Continuous Second Zone Oscillating Mode.
It defines the deflection range in degrees as a symmetrical oscillation with respect to the fixed angle (-15°).
Selections: a value from
10°
to
40°
:
Second Zone Frequency (Hz)
This parameter is available only when working in Continuous Second Zone Oscillating Mode.
It defines the oscillating frequency in Hertz:
Selections: a value from
0.5
to
4.0
Hertz:
NOTE
The maximum allowable frequency for an amplitude of 35° or more is 3 Hz.
TCNM-SPLD-OM Oscillating Mirror
NOTE
This parameter group is available only for
TCNM-SP
scanners (Oscillating Mirror models).
Oscillating Mode
This parameter defines the oscillating mode of the scanner mirror: