TCNM-AD/EX/SP Family Software Configuration Parameter Guide
22
Start Input Active Level
Allows the selection of the active state of the input.
Selections:
Active Open
the input is active when there is no current flowing through IN pins.
Active Closed
the input is active when current flows through IN pins.
Stop Input Number
It defines the number of the input ending the reading phase.
Selections: from
1
to
2
Stop Input Active Level
Allows the selection of the active state of the input.
Selections:
Active Open
the input is active when there is no current flowing through IN pins.
Active Closed
the input is active when current flows through IN pins.
Stop Phase Edge
This parameter is available only when On Line Options = On Line 2 Inputs.
It allows defining the signal edge of the stop input used by the scanner as reference for ending the reading phase:
Selections:
Trailing
the reading phase ends when the pack has completely passed by the stop input.
Leading
the reading phase ends as soon as the stop input detects the front edge of the pack.
Serial Start String
The Serial Start string signals the beginning of the reading phase.
Selections: a character from
NUL
(00H) to
~
(7EH)
The Serial Start string must be different from the Serial Stop string and Motor ON/OFF strings. When ACK/NAK
Protocol or Energy Saving are enabled, the Serial Start/Stop Strings cannot contain ACK/NAK characters.
Serial Stop String
The Serial Stop string signals the end of the reading phase.
Selections: a character from
NUL
(00H) to
~
(7EH)
The Serial Stop string must be different from the Serial Start string and Motor ON/OFF strings. When ACK/NAK
Protocol or Energy Saving are enabled, the Serial Start/Stop Strings cannot contain ACK/NAK characters.
Reading Phase Timeout
If checked, it allows defining a timeout for the Serial On Line mode and the On Line 1 Input mode.
Timeout
By setting this parameter the reading phase starts when the Start Input or Serial Start String is activated and stops
when the selected Timeout expires. The Timeout represents the period of time for the reading phase.
Selections: from
40
to
15000
ms
Timeout Counting From
This parameter determines whether the Timeout used to determine the reading phase will begin from the Start Input
or Serial Start String (normal operation), or from the Stop Input or Serial Stop String (effectively extending the
reading phase.
Selections:
Start
or
Stop