Digital I/O Setting
61
Activate on any Diagnostics Error
If this parameter is checked, the output will activate when a diagnostic error message is sent, independent from the
event counter parameter. This parameter has priority over all other activation, deactivation, and timeout events.
Deactivate when all Diagnostics Errors Recovered
If this parameters is checked, the output will deactivate when there are no more diagnostic error message to send.
Deactivation Timeout
Indicates the maximum duration of the output pulse measured in milliseconds.
Selection: value from
40
to
15000
NOTE
All values defined for this parameter will be rounded up to the nearest multiple of 20 ms.
Event Counter
The Event Counter parameter defines the number of occurrences of the activation event and/or alternative activation
event that must transpire before the output can be activated. These occurrences can be either consecutive or not
consecutive as described in the Event Counter Mode parameter. Once this value is reached the counter is reset and
starts recounting.
Selection: value from
1
to
70000
NOTE
This parameter is recommended only for On-Line or Serial On Line operating modes.
Event Counter Mode
Selection:
Consecutive
This counter only counts events that occur in consecutive reading phases. The output is
activated after the Event Counter value is reached. If the event is not consecutive the
counter is reset.
Not
Consecutive
This counter totals all events, even when occurring at non-consecutive reading phases.
The output is activated according to the Message Tx Selection parameter after the Event
Counter value is reached.
NOTE
Not all Activation Event and Alternative Activation Event combinations are meaningful.
The Phase ON and Phase OFF events are only managed as totals, independent from the Event
Counter Mode selection.
The Ready event has no count associated with it and therefore the Event Counter and Event
Counter Mode parameters are ignored.
Quality Counter Threshold
This parameter sets the number of Quality Counter good decodes that serve as the threshold for one of the
Activation/Deactivation events.
Selection: value from
1
to
100