TCNM-AD/EX/SP Family Software Configuration Parameter Guide
68
Laser Temperature Sensor: Communication Error
If checked, it allows sending an alarm whenever there is a communication error between the decoder board and the
Laser Temperature Sensor.
Temperature Sensors Mismatch Error
If checked, it allows sending an alarm whenever the internal Temperature Sensors values don't match.
Low Temperature Alarm
If checked, it allows sending an alarm whenever the internal temperature falls below the threshold of 0 °C indicating
the scanner is operating outside of its specifications. To avoid component damage, the scanner will enter a sort of
standby condition where the laser, motor, display and oscillating mirror (for OM models) are turned off until the
internal temperature returns to within the normal operating range. The Ready LED also blinks in this condition.
High Temperature Warning
If checked, it allows sending an alarm whenever the internal temperature has reached the maximum level. The
scanner life and/or performance may be reduced. Continued operation at this level could cause the scanner to fail.
Low Power Supply Alarm
If checked, it allows sending an alarm whenever the input power to the scanner falls below an internal threshold which
depends on the model:
TCNM-SP < 8 Vdc
Operation at this level is not guaranteed and may reduce performance.
Fieldbus Failure
If checked, it allows sending an alarm whenever there is a communication error between the scanner and the Fieldbus
module inside the TCNM-ACBB5 connection box.
Fieldbus Configuration Error
If checked, it allows sending an alarm whenever a configuration error has occurred between the scanner and the
Fieldbus module inside the TCNM-ACBB5 connection box.
Fieldbus DHCP Problem
If checked, it allows sending an alarm whenever there is a communication problem between the DHCP server and the
Fieldbus module inside the TCNM-ACBB5 connection box.
Fieldbus Mismatch
If checked, it allows sending an alarm whenever the Fieldbus module inside the TCNM-ACBB5 doesn't match the one
saved in the scanner configuration memory.
Wrong TCNM-ACBB Backup Module Rotary Switch Selection
If checked, it allows sending an alarm whenever one or more of the selected Backup module Rotary Switch settings
inside the TCNM-ACBB doesn't match the scanner configuration memory.
TCNM-ACBB Backup Module Communication Failure
If checked, it allows sending an alarm whenever there is a communication error between the scanner and the Backup
module inside the TCNM-ACBB connection box.