Data Communication Settings
37
Data Format
Data Format allows to configure the parameters relative to the message format and the transmission mode:
Header Tx Start
It selects the transmission of the header
after the reading phase
activation or
with data
.
Selections:
After Reading Phase On
header will be transmitted after the reading phase activation
With Data
header will be transmitted with data
Example
Header Position
Termination After No Read Message
This parameter is available only when the No Read Message parameter is set to "Global No Read Message" or "Local
No Read Message".
If checked (enabled), the Termination String is added to the No Read message string.
Message Tx Selection
Message Tx Selection selects the transmission of the output message either on decoding or after the reading phase.
Selections:
On decoding
After Reading Phase Off
Delayed Tx Line
(only for On-Line operating mode)
Physical Encoder
This parameter is available only when Message Tx Selection is set to Delayed Tx Line. If checked, it enables the
encoder which is physically connected to the Input selected in Encoder Reference Signal. For correct functioning,
define the Encoder Step parameter (hundredths of a millimeter) and ensure that the Debouncing value for the Input is
5 ms. The maximum allowable Encoder Frequency is 150 Hz.
If unchecked, the conveyor speed is supposed to be constant. Thus, it is only required to define the Conveyor Speed