TCNM-AD/EX/SP Family Software Configuration Parameter Guide
80
On Line 1 Input with Conveyor Info Available
Diagnostics
Error Number
Meaning
[132]
Presence Sensor Warning
: the conveyor moves but the presence sensor remains
closed for more than the programmed No Phase timeout. This message may
indicate that no pack is present on the conveyor.
[149]
Presence Sensor Failure
: the conveyor moves but the presence sensor remains
open for more than the programmed Presence Sensor Stuck timeout. This message
may indicate a presence sensor failure or physical misalignment. Take into
consideration the calculation of the maximum period of time required by the
package to pass through the reading area.
On Line 1 Input without Conveyor Info Available
Diagnostics
Error Number
Meaning
[132]
Presence Sensor Warning
: the presence sensor remains closed for more than the
programmed No Phase timeout. This message may indicate that no pack is present
on the conveyor.
[149]
Not available
On Line 2 Inputs with Conveyor Info Available
Diagnostics
Error Number
Meaning
[131]
PS Input Failure
: the conveyor moves and the PS Output is active while the PS
Input is inactive. Or the conveyor is not moving and the PS Output is inactive while
the PS Input is active. The correct synchronization of the two presence sensors is
periodically checked by counting the number of their status changes within a
sampling period of 4 minutes.
[132]
Presence Sensor Warning
: the conveyor moves but both the presence sensors
remain closed for more than the programmed No Phase timeout. This message may
indicate that no pack is present on the conveyor. Furthermore, it is assumed that
both presence sensors are correctly synchronized otherwise a [131] or [133] error
would be generated.
[133]
PS Output Failure
: the conveyor moves and the PS Input is active while the PS
Output is inactive. Or the conveyor is not moving and the PS Input is inactive while
the PS Output is active. The correct synchronization of the two presence sensors is
periodically checked by counting the number of their status changes within a
sampling period of 4 minutes.
[149]
Presence Sensor Failure
: the conveyor moves but both the presence sensors
remain open for more than the programmed Presence Sensor Stuck timeout. This
message may indicate both presence sensors have failed or are physically
misaligned. It is assumed that both presence sensors are correctly synchronized
otherwise a [131] or [133] error would be generated. Take into consideration the
calculation of the maximum period of time required by the package to pass through
the reading area.
On Line 2 Inputs without Conveyor Info Available
Diagnostics
Error Number
Meaning
[131]
PS Input Failure
: the PS Output is active while the PS Input is inactive. When no
information about movement is provided, it is assumed that the broken presence
sensor is the one which does not signal the packs entering the tracking area. The
correct synchronization of the two presence sensors is periodically checked by
counting the number of their status changes within a sampling period of 4 minutes.