TCNM-AD/EX/SP Family Software Configuration Parameter Guide
82
Slave Address
When setting the scanner topology role to Slave, it is necessary to define the ID-NET™ slave address within the
network (1..31).
Operating Mode Reference Table
The following table summarizes all the conditions determining the use of each operating mode:
Operating
Mode
Code Combination
Topology Role
P.S.
Single
Label
Standard
Multilabel
Logical
Combination
Code
Collection
Other
Stand
Alone
Master
Synchronized
Slave
Synchronized
Master/Slave
Multidata
HW/SW
On Line
X
X
X
X
X
X
X
X
X
Automatic
X
X
X
X
X
---
---
X
---
Continuous
X
---
---
---
X
---
---
X
---
Test
1
---
---
---
---
---
---
---
---
---
1
This operating mode does not require particular conditions.
Standard Message Format
Information relative to code reading is transmitted in standard formats on the selected serial interface(s).
The general format is:
<HEADER><DATA><TERMINATOR>
The decoding result can be one of the following:
DECODED CODE
NO READ
WRONG READ (Code Verifier)
DIAGNOSTIC MESSAGES
A combination of the first two results can be obtained when using multilabel codes.
The following applies to message structures and transmission features:
1) Header Field can be transmitted at the start of the reading phase or together with the Data.
2) The Data and Terminator Fields can be transmitted as soon as decoding is over or at the end of the reading phase.
Decoded Code
Format
For Single Label:
<DATA> = <DATA PACKET>
For Multi Label:
<DATA> = <DATA PACKET #1><DPS><DATA PACKET #2><DPS>...<DATA PACKET #n>
where: