Operating Modes
27
Enable
When checked it enables the Code Verifier operating mode.
Verifier Code
The string used as the match code to the decoded codes.
Selections: characters from
NUL
(00H) to
~
(7EH)
Store Input
It defines the number of the input used to automatically store the verifier code. This input must be activated before
the reading phase starts, the verifier code must be read and then after the end of the reading phase the input must be
deactivated.
Selections: from
1
to
2
Active Level
Allows the selection of the active state of the input.
Selections:
Active Closed
the input is active when current flows through IN pins.
Active Open
the input is active when there is no current flowing through IN pins.
Right Code Tx
When checked it enables the transmission of the Right Code.
Wrong Code Tx
When checked it enables the transmission of the Wrong Code.
Wrong String Tx
When checked it enables transmission of the Wrong String message.
Wrong String
The string sent in case of a mismatch (wrong code read).
Selections: characters from
NUL
(00H) to
~
(7EH)