Diagnostics
71
User Defined Message Examples
Stand Alone
<STX>#<BEL><ETX>
Motor Failure (default string)
<STX>#Motor Failure<ETX>
"Motor Failure" (user defined string)
Master
<STX>00#<BEL> 01#^<ETX>
Master (00) digitizer motor failure (default string) +
Slave 01 not responding (default string)
<STX>00#Motor Failure 01#Slave
Not Responding<ETX>
"Motor Failure" + "Slave Not Responding" (user defined
strings)
Local Network Failure
It defines the message string (up to 128 bytes) that will be sent as a diagnostic message whenever the local ID-NET™
network controller failure is present.
Motor Failure
For TCNM-AD/EX scanners, it defines the message string (up to 128 bytes) that will be sent as a diagnostic message
whenever the motor speed is above or below the internal threshold with respect to the programmed Scan Speed.
Laser Failure
For TCNM-AD/EX scanners, it defines the message string (up to 128 bytes) that will be sent as a diagnostic message
whenever a laser failure has occurred.
Oscillating Mirror Failure
For TCNM-AD/EX scanners, it defines the message string (up to 128 bytes) that will be sent as a diagnostic message
whenever the oscillating mirror has not been recognized.
Oscillating Mirror Data Consistency Error
For TCNM-AD/EX scanners, it defines the message string (up to 128 bytes) that will be sent as a diagnostic message
whenever a checksum error has occurred on the oscillating mirror onboard settings.
Start/Stop Input Failure
It defines the message string (up to 128 bytes) that will be sent as a diagnostic message whenever a start/stop input
failure is present.
Presence Sensor Stuck Timeout
It defines the message string (up to 128 bytes) that will be sent as a diagnostic message whenever a presence sensor
stuck timeout is present.
No Phase Warning
It defines the message string (up to 128 bytes) that will be sent as a diagnostic message whenever the No Phase
Timeout expires (no phase activity - on or off).
Focus Displacement
It defines the message string (up to 128 bytes) that will be sent as a diagnostic message whenever the actual focus
position doesn't match the Locked Position saved in the scanner configuration memory. This alarm is generated when
the focus position has exceeded the allowable tolerance.
DIGITIZER: Motor Failure
It defines the message string (up to 128 bytes) that will be sent as a diagnostic message whenever the motor speed is
above or below the internal threshold with respect to the programmed Scan Speed.