TCNM-AD/EX/SP Family Software Configuration Parameter Guide
78
All
[149]
Presence Sensor Failure:
presence sensor(s) remain open for more than the
programmed Presence Sensor Stuck timeout.
All
[151]
Local Network Failure:
a local ID-NET™ network controller error has
occurred.
All
[185]
TCNM-ACBB Backup Module Communication Failure:
there is a
communication error between the scanner and the Backup module inside the
TCNM-ACBB connection box.
All
[187]
Wrong TCNM-ACBB Backup Module Rotary Switch Selection:
one or more
of the selected Backup module Rotary Switch settings inside the TCNM-ACBB
doesn't match the scanner configuration memory.
All
[189]
Fieldbus Failure:
there is a communication error between the scanner and the
Fieldbus module inside the TCNM-ACBB5 connection box.
All
[191]
Fieldbus Mismatch:
the Fieldbus module inside the TCNM-ACBB5 doesn't
match the one saved in the scanner configuration memory.
All
[193]
Fieldbus Configuration Error:
a configuration error has occurred between the
scanner and the Fieldbus module inside the TCNM-ACBB5 connection box.
All
[195]
Fieldbus DHCP Problem:
a communication problem has occurred between the
DHCP server and the Fieldbus module inside the TCNM-ACBB5 connection box.
SP
[197]
Low Temperature:
indicates the scanner is operating below its minimum
internal temperature specification limit of 0°C; scanner in standby.
SP
[199]
Low Power:
the scanner is operating below the minimum input power
threshold value depending on the model.
Some of these error messages may have different meaning according to different conditions.
See also Note 2.
Master only
Diagnostic
Error Number
Meaning
[1]
Slave xx No Reply
: no response from slave number
xx
, where xx is the slave
address.
[64]
Slave Address xx Duplication
: two or more slaves have the same address xx.
[80]
Slave xx Net Configuration
: slave xx has been (re)configured.
NOTE 1
Errors [1] and [80] may be detected whenever any scanner configuration changes.
Error [64] may be detected a few minutes after the problem is generated and it is
maintained until the master scanner configuration changes or until the next power cycle
of the master scanner itself.
Error [1] may be detected before Error [64] is detected due to the latency required for
Error [64] detection.
SYNCHRONIZED Slave only
Family Diagnostic
Error
Number
Meaning
AD/EX [81]
Motor Failure:
the motor speed is above or below the internal threshold with
respect to the programmed Scan Speed.
SP
[81]
DIGITIZER:
Motor Failure
the motor speed is above or below the internal
threshold with respect to the programmed Scan Speed.
AD/EX [83]
Laser Failure:
a laser failure has occurred.
SP
[83]
DIGITIZER:
Laser Failure
a laser failure has occurred.
SP
[85]
DIGITIZER:
Data Consistency Error
a checksum error has occurred on the
analog board EEPROM memory.
SP
[87]
DIGITIZER:
Communication Error
there is a communication error between
the decoder board and the analog board.
SP
[89]
DIGITIZER:
Reset
an unexpected analog board reset has occurred.
SP
[91]
DIGITIZER:
Data Write Error
a data write error has occurred to the analog
board EEPROM memory.
SP
[93]
Focus Displacement
the actual focus position doesn't match the Locked
Position saved in the scanner configuration memory. This alarm is generated
when the focus position has exceeded the allowable tolerance.