References
77
References
Diagnostic Error Conditions
The following tables summarize all Internal Numeric Error Messages generated when working in the network.
Diagnostic Error Messages
Stand Alone / Master/ MULTIDATA Slave
Family Diagnostic
Error
Number
Meaning
AD/EX [81]
Motor Failure:
the motor speed is above or below the internal threshold with
respect to the programmed Scan Speed.
SP
[81]
DIGITIZER:
Motor Failure
the motor speed is above or below the internal
threshold with respect to the programmed Scan Speed.
SP
[82]
DIGITIZER:
Motor Life End
the motor has surpassed its factory declared
functional life.
AD/EX [83]
Laser Failure:
a laser failure has occurred.
SP
[83]
DIGITIZER:
Laser Failure
a laser failure has occurred.
SP
[84]
DIGITIZER:
Laser Life End
the laser has surpassed its factory declared
functional life.
SP
[85]
DIGITIZER:
Data Consistency Error
a checksum error has occurred on the
analog board EEPROM memory.
SP
[87]
DIGITIZER:
Communication Error
there is a communication error between
the decoder board and the analog board.
SP
[89]
DIGITIZER:
Reset
an unexpected analog board reset has occurred.
SP
[91]
DIGITIZER:
Data Write Error
a data write error has occurred to the analog
board EEPROM memory.
SP
[93]
Focus Displacement
the actual focus position doesn't match the Locked
Position saved in the scanner configuration memory. This alarm is generated
when the focus position has exceeded the allowable tolerance.
AD/EX [97]
Oscillating Mirror Failure
the oscillating mirror has not been recognized.
SP
[97]
OSCILLATING MIRROR:
Motor Failure
the oscillating mirror motor speed is
above or below the internal threshold with respect to the programmed
Frequency.
SP
[98]
OSCILLATING MIRROR:
Motor Life End
the oscillating mirror motor has
surpassed its factory declared functional life.
AD/EX [99]
Oscillating Mirror Data Consistency Error
a checksum error has occurred on
the oscillating mirror onboard settings.
SP
[99]
OSCILLATING MIRROR: Data Consistency Error
a checksum error has
occurred on the oscillating mirror onboard settings.
SP
[101]
OSCILLATING MIRROR: Communication Error
there is a communication
error between the decoder board and the oscillating mirror board.
SP
[103]
OSCILLATING MIRROR: Reset
an unexpected oscillating mirror board reset
has occurred.
SP
[105]
OSCILLATING MIRROR: Data Write Error
a data write error has occurred to
the oscillating mirror board EEPROM memory.
SP
[119]
Reading Conditions Controller: Communication Error
there is a
communication error between the decoder board and the Reading Conditions
Controller.
SP
[121]
Focus Controller: Communication Error
there is a communication error
between the decoder board and the Focus Controller.
SP
[123]
Temperature Sensor: Communication Error
there is a communication error
between the decoder board and the Temperature Sensor.
SP
[124]
High Temperature Warning:
the internal temperature has reached the
maximum level. The scanner life and/or performance may be reduced.
Continued operation at this level could cause the scanner to fail.
SP
[125]
Laser Temperature Sensor: Communication Error
there is a communication
error between the decoder board and the Laser Temperature Sensor.
SP
[127]
Temperature sensors Mismatch Error:
the internal Temperature Sensors
values don't match.
All
[131]
/
[133]
Start/Stop Input Failure:
the start or stop input is not working.
All
[132]
No Phase Timeout:
no reading phase for more than the programmed No
Phase timeout.