References
79
AD/EX [97]
Oscillating Mirror Failure
the oscillating mirror has not been recognized.
SP
[97]
OSCILLATING MIRROR:
Motor Failure
the oscillating mirror motor speed is
above or below the internal threshold with respect to the programmed
Frequency.
AD/EX [99]
Oscillating Mirror Data Consistency Error
a checksum error has occurred
on the oscillating mirror onboard settings.
SP
[99]
OSCILLATING MIRROR: Data Consistency Error
a checksum error has
occurred on the oscillating mirror onboard settings.
SP
[101]
OSCILLATING MIRROR: Communication Error
there is a communication
error between the decoder board and the oscillating mirror board.
SP
[103]
OSCILLATING MIRROR: Reset
an unexpected oscillating mirror board reset
has occurred.
SP
[105]
OSCILLATING MIRROR: Data Write Error
a data write error has occurred to
the oscillating mirror board EEPROM memory.
SP
[119]
Reading Conditions Controller: Communication Error
there is a
communication error between the decoder board and the Reading Conditions
Controller.
SP
[121]
Focus Controller: Communication Error
there is a communication error
between the decoder board and the Focus Controller.
SP
[123]
Temperature Sensor: Communication Error
there is a communication error
between the decoder board and the Temperature Sensor.
All
[151]
Local Network Failure:
a local ID-NET™ network controller error has
occurred.
All
[185]
TCNM-ACBB Backup Module Communication Failure:
there is a
communication error between the scanner and the Backup module inside the
TCNM-ACBB connection box.
All
[187]
Wrong TCNM-ACBB Backup Module Rotary Switch Selection:
one or more
of the selected Backup module Rotary Switch settings inside the TCNM-ACBB
doesn't match the scanner configuration memory.
Some of these error messages may have different meaning according to different conditions.
NOTE 2
All
DIGITIZER, OSCILLATING MIRROR, and FLASH
errors, except for: DIGITIZER Motor
Warning, Focus Displacement, and High Temperature Warning, require that the relative scanner be
reset before the error can be cancelled.
Error Message Conditions
A single error number can indicate different types of failure according to the following conditions:
working in On Line mode with 1 input and Conveyor Info available
working in On Line mode with 1 input and without Conveyor Info available
working in On Line mode with 2 inputs and with Conveyor Info available
working in On Line mode with 2 inputs and without Conveyor Info available
working in Serial On Line mode
In the following description the following expressions are used:
"presence sensor open"
=
the presence sensor light beam is broken
"presence
sensor
closed"
=
the presence sensor light beam is continuous
On Line Operating Mode
When working in On Line operating mode the meaning of an error message can change according to the selection of
the On Line Options parameter and to the selection of the Conveyor Info parameter.