Data Communication Settings
45
Auxiliary Serial Port
This group determines the communication through the Auxiliary Serial Port (RS232 only). This port is also available to
MULTIDATA Slave scanners.
Search for TCNM-ACBB Backup Module at Device Startup
If enabled (checked), at startup, the scanner sends a message to recognize the presence of, and communicate with,
the Backup Module. If using the Backup Module, this parameter must be enabled (checked).
NOTE
Disable this parameter if the Backup Module is not used and the Host must not receive data at
startup.
Data TX
If enabled (checked), data from the scanner will be transmitted on the Auxiliary Serial Port.
Heartbeat
This parameter enables/disables transmission of the Heartbeat message used to signal device or system status at
regular intervals. The Heartbeat message is independent from Data Tx and can be enabled even if data is not sent on
the Auxiliary Serial Port (Data Tx - disabled).
Selections:
Disable
the Heartbeat message is not transmitted
Enable Unconditioned
the Heartbeat message is always transmitted, even if
communication is still active
Enable Conditioned
the Heartbeat message is transmitted only when there is no
communication
Pass Through
It enables/disables the Pass Through options.
Heartbeat
The following parameters allow configuring the Heartbeat message for communication through the Auxiliary Port.
The Heartbeat message is used to signal the device's or system's status at regular intervals to the Host. It has the
following format:
Timeout
This parameter defines the amount of time between two message transmissions. If the selected time out expires and
no transmission has occurred, the Heartbeat message will be transmitted.
Heartbeat Header String
This parameter signals the beginning of the Heartbeat message. It can be a string of up to 128 characters.
Selections: characters from
NUL
(00H) to
~
(7EH)
The Heartbeat Header String should be different from the Heartbeat Terminator String.