TCNM-AD/EX/SP Family Software Configuration Parameter Guide
44
Handshake
Handshake is a communication control used to protect against data loss, it can be achieved via hardware (RTS\CTS
protocol) or software (Xon\Xoff protocol).
Selections:
None
Hardware
(RTS/CTS)
Software
(Xon/Xoff)
Baud Rate
Baud rate is the transmission speed in a communication line.
Selections: from
1200
to
115200
Parity
Parity is a parameter indicating the presence of a control bit in the communication protocol frame.
Selections:
None
Odd
Even
Data Bits
Data Bits is a parameter indicating the number of bits composing the data packet of the communication protocol
frame.
Stop Bits
Stop Bits is a parameter indicating the number of stop bits in the data packet of the communication protocol frame.
Mux32 Protocol Address
When MUX32 Communication Mode is selected, it is possible to define an address for the connection of the scanner
with a Multiplexer.
Selections: a value from
0
to
31
Checksum
If
checked
, it enables the Checksum parameter. It is a control byte of the communication protocol. It is the one that
distinguishes the normal protocol from the R version of the Siemens protocol itself (3964 from 3964R).
Priority
Priority is a parameter indicating the priority of the local node with the 3964 link.
Selections:
Low
High
Header Bytes
RK512 frame header is composed of 10 bytes. The values of bytes 5, 6, 9 and 10 must be defined.
Filler Character
The Fill character parameter indicates the value of the filler byte added by RK512 protocol if an odd number of bytes
has to be transmitted.
Filler Position
The Fill position parameter indicates the position (at the beginning or at the end of the data packet) of the filler byte
added by RK512 protocol if an odd number of bytes has to be transmitted.
Selections:
After data