TCNM-AD/EX/SP Family Software Configuration Parameter Guide
32
Focus
Locked Position (cm/in)
This parameter allows the scanner focus position to be saved in memory. If the physical focus position changes with
respect to the saved value, an alarm can be generated (message on the scanner display, TCNM-ACBB5 display,
diagnostic message on the selected interface).
Selections:
Unlocked
the focus position is not stored in memory. Changes in the focus
distance do not generate any alarms.
a value between
25 cm/9.84 in
and
70 cm/27.56 in
.
NOTE
Changing this parameter causes the scanner to reset, and therefore, if the scanner motor has
been set to
off
by the Energy Saving/Serial Motor OFF parameters, the motor will automatically be
restarted upon reset.
TCNM-ACM-OM110 Oscillating Mirror
NOTE
This parameter group is available only for
TCNM-AD/EX family
scanners with Oscillating Mirror.
Oscillating Mode
This parameter defines the oscillating mode of the scanner mirror:
Selections:
Fixed
the oscillating mirror deflects the scan line at a fixed angle of
deflection (-15°).
Continuous
the scan line is deflected according to the Amplitude and Frequency
settings.
Amplitude (degrees)
This parameter is available only when working in Continuous oscillating mode.
It defines the deflection range in degrees as a symmetrical oscillation with respect to the fixed angle (-15°).
Selections: a value from
10°
to
40°
:
Frequency (Hz)
This parameter is available only when working in Continuous oscillating mode.
It defines the oscillating frequency in Hertz:
Selections:
a value from
0.5
to
4.0
Hertz
NOTE
The maximum allowable frequency for an amplitude of 35° or more is 3 Hz.