TCNM-AD/EX/SP Family Software Configuration Parameter Guide
88
6.
Set the GeniusPlus Tools>Options>Communications window to TCP/IP and in the Device address or name
field, input the scanner Factory Default address. The port number is 51235. Then click
OK
.
7.
Perform a Device>Get (configuration) from GeniusPlus.
Using the Serial Interface
1.
Connect to GeniusPlus through the RS232 Serial Port (enabled by default) and the scanner Aux RS232 port.
2.
Perform a Device>Get (configuration) from GeniusPlus.
3.
Set the Data Communication Setting>TCNM-ACBB5 Gateway>Type to
Ethernet TCP/IP
and the desired Line
Parameters>IP Addressing parameters.
4.
Send the configuration to the scanner.
5.
Set the GeniusPlus Tools>Options>Communications window to TCP/IP and in the Device address or name
field, input the IP address. The port number is 51235. Then click
OK
.
6.
Exit from GeniusPlus. The next connection will take place using the configured IP addressing.